Preface

Thank you for purchasing the new voltage detector. In order to use 

this product safely and correctly, please read this manual thoroughly, 

especially the Warning part.
After reading this manual, it is recommended to keep the manual at 

an easily accessible place, preferably close to the device, for future 

reference.

Overview

The KN 8065 series products are non-contact voltage detectors with 

built-in flashlight and acousto-optic synchronous alarm function. 

The CAT IV 1000V safety class ensures users’ safety, making them 

essential tools for industry and home.

Low voltage mode (24V AC ~ 1000V AC)

(KN 8065-E only):

Suitable for testing low-voltage motor (< 90V), audio systems,

arc welding machines, underground mine lighting, cables with thick 

insulation layer, and other weak electromagnetic AC signals.

High voltage mode (90V AC ~ 1000V AC):

For detecting urban electric supply and three-phase systems.

For example, power distribution units, electrical panels,

electrical appliances.

         1. Please carefully read and fully understand the warnings and

             operating instructions before use. If the equipment is used in

             a manner not specified by the manufacturer, the protection

             provided by the equipment may be impaired.

  2. Please test the detector on a known live source within the rated

      AC voltage range before use.

  3. If the detector appears damaged or is not working properly, stop

      using it immediately.

  4. Do not detect voltage higher than 1000V.

  5. Use caution when working with voltages above AC 30Vr.m.s,

      42V peak or DC 60V. Such voltages pose a shock hazard.

      Clean the tester casing with a damp cloth and mild detergent.

      Do not use abrasives or solvents!

  6. There may still be voltage even when no acousto-optic alarm is on.

  7. The insulation type, wire thickness, distance from voltage source,

      shielded wire, other wires, socket design, and other factors may

      adversely affect test result. If there are uncertainties, use other

      methods to verify the voltage.

  8. Do not assume neutral or ground wire is safe to touch. Incorrect 

      or poorly connected circuits may cause wires to be charged.

  

  9. When low battery indication appears, please replace the batteries.

WARNING

Voltage

tester