Knoll MVP44A Скачать руководство пользователя страница 7

10

7

8. 

Connect the emitters to the IR Emitter ports on the rear of the

MVP44a. Single or dual emitters can be used. If a Xantech 590-00 is
being installed do not connect emitters in the MVP44a IR Emitter #1.

9.

 When connecting two or more MVP44a's in the same home,

connect the amps together using stereo 3.5mm plugs (all three wires are
used) to the data plug on the rear of the MVP44a. The MVP44a's
share power on and off data as well as infrared signals.

         The MVP44a source input RCA jacks are Y-corded
         together on all amps (source 1 left/right on amp 1
         to source 1 left/right on amp 2 etc.)

10.

 Connect the AC power into an outlet that can supply at least six

amps (700 watts) dedicated to each MVP44a.

11.

 If a Xantech 590-00 is to be installed, the 590-00 needs to be

wired to the MVP44a removable 8 terminal connector and the
590-00 has to be programmed.

Wiring the 590-00 to the MVP44a

The wire/plug from the 590-00 IR emitter port 1 is a mono 3.5mm
with the stripewire to the center/end of the 3.5mm connector. The
rest of the wires can be almost any type.

MVP44a to Xantech 590-00

The Xantech 590-00 is an infrared learning "remote" capable of
converting a dry contact closure of each of the MVP44a's four
functions, power-on (TON) and power-off (TOFF) to an IR
macro sequence of up to 10 commands each.

The 590-00 power supply is shipped with the 590-00. Power to
the 590-00 should be on all the time (like a TV set) so the system
IR commands can be sent as soon as any MR60 source buttons are
pressed.

The first time installing and programming a 590-00 connected to a
MVP44a can be a bit tricky, so please follow these directions closely.

See the diagram on page 7.

Connect the 590-00 rear panel "O" and "G"  terminals to the wire pair
on the 3.5mm to wire pair (installer supplied). Connect the black wire
with the stripe to the "O". Next insert the 3.5mm plug into the rear of
the MVP44a labelled "IR Emitters" and "1".

With any type of single conductor wire connect the 590-00 bottom
row - terminals 1, 2, 3, 4, 5, 6 and the -12VDC terminal.

DO NOT connect any wires to the TRIG
terminal on the MVP44a at this time

.

Now connect the MVP44a terminal FD to the 590-00 top row +
terminal 1. Next connect the MVP44a terminal FC to the 590-00 top
row + terminal 2.

Continue by individually connecting the MVP44a FB, FA, TOFF and
TON to the 590-00 top row + terminal 3, 4, 5 and 6. If all of the
source equipment has the same IR commands for power-on and
power-off, move the wire on the 590-00 connected to te5
(on the + row) with the wire on the 590-00 te6.

Содержание MVP44A

Страница 1: ...tate Kn ll products sold outside of Canada and the USA may be covered by warranties provided by an authorized Kn ll distributor Please contact the distributor in the country that the Kn ll product was...

Страница 2: ...urn off and on together and share infrared signals page connect to door chimes connect to external controllers etc 8 Cooling fan Fans maximize system performance and helps to avoid earlyprotectionsyst...

Страница 3: ...d to4ohmloadsmayoccasionallyshutdownduetooverloading Never connect the MVP44a to 2 ohm loads TheMVP44ahasacoolingfantoincreaselongtermpoweroutput and reliability continued 14 3 possible in the sequenc...

Страница 4: ...commands on each of its four banks If more than 10 different IR commands are to be stored use bank 2 3 and 4 to store the sequence commands and bank one positions 1 6 to execute the sequences 1 Write...

Страница 5: ...e 590 00 and the MVP44a The 590 00 can learn up to 16 different commands on each of its four banks If more than 10 different IR commands are being stored use bank 2 3 and 4 to store the sequence comma...

Страница 6: ...the keypads are not working properly or not controlling at all Check the MR60 dip switch settings wiring layout and crimp as well as bank connections very carefully MR60 1 2 3 4 MVP44a Activation The...

Страница 7: ...drycontactclosureofeachoftheMVP44a sfour functions power on TON and power off TOFF to an IR macro sequence of up to 10 commands each The 590 00 power supply is shipped with the 590 00 Power to the 590...

Страница 8: ...our function selection buttons Three bar volume level indicators blinks at min or max Volume up and down this room only or whole house when FNC selected MR60 keypad functions OFF FNC MUTE 3 4 1 2 DN U...

Отзывы: