Knoll MVP44A Скачать руководство пользователя страница 6

6

11

7. 

Install MR60 keypads (or infrared receivers) in the rooms with

the speakers. Cat 3 or cat 5 wire can be home run to the MVP44a or
up to three rooms daisy chained on one wire.

  ***Be sure to set the dip switch on the rear of the MR60***

See the dip switch adjustment below. Connect all eight individual
wires using RJ45 connectors. Four wire conductors are needed for
each keypad (one unique, common: IR , ground and 12VDC).

MR60 Dip Switch
Adjustment

Use either RJ45
connector as they
are in parallel

The rear of the MR60 is shown. Because one to three MR60's can
be connected or daisy chained to the same cat 5 wire, the keypad
position on the wire must be selected using the dip switch. The two
MR60 RJ45 connectors are in parallel. Only one dip switch slider
should be on and the other two off (#1 is shown on in this example).
The MR60 1-2-3 dip switch positions correspond to MVP44a keypad
ports and speaker outputs A3 or B1-B2-B3.

***Even if the keypads are home run, the

        MR60 dip switch position has to be selected***

If three keypads are daisy chained on one wire, select the MR60
dip switch on the first MR60 to one, the second MR60 to two and
the third MR60 to three. At the rear of the MVP44a, the RJ45
connector from the three MR60 keypads can be connected any
corresponding keypad Bank A3 or Bank B;  port 1, 2 or 3. The
corresponding speaker outputs will be the same number as selected
on the MR60 keypad (example: the MR60 keypad with #2 dip on
and connected to MVP44a keypad bank B will control speaker
outputs B2R and B2L).

  After installation, if the keypads are not working properly or not
  controlling at all, Check the MR60 dip switch settings, wiring
  layout and crimp as well as bank connections very carefully.

MR60

1 2 3 4

MVP44a Activation

The 590-00 generates infrared command sequences when a
momentary pulse from any of the six MVP44a function outputs are
activated. Source A is usually reserved for CD use. When the MVP44a
is powered up someone pushing a MR60 Source button or RB8
remote source, the power on (TON) pulse is activated.

Some 

examples

 to understand when MVP44a pulses are activated

and the 590-00 macro sequencies are initiated are listed below:

Note

: None of the functions below work when any MR60 leds are

blinking to indicate MUTE activated.

Pulse O/P

Activates when:

Example IR sequence:

Power On

Any MR60 or RB8 source

Sequence power (on)

(TON)

key is pushed when all

command to all

MR60 leds are off.

source components

F A

FNC then Source A (CD)

CD skip, CD play or

 (source A

key pushed when system's on CD random

 CD player)

and no MR60 blinking led's.

F B

FNC then Source B (FM or

CD skip to next disk

 (source B

AUX1)  key pushed when

 Jazz station) the system is on.

F C

FNC then Source C (Dish

Scan to next news

  (source C

AM or CD2) key pushed

station programmed

  news tuner) when the system is on.

into news tuner

F D

FNC then Source D (AUX or Scan up one station

 (source D

AUX2) key pushed when

 sat dish#2)

the system is on.

Programming the 590-00

IR functions do not have to be related to the source input. For
example, if source A is a CD player and source B is a jazz tuner,
function A could be a sequence of CD skip, CD play, and CD
random. Function B could be CD Skip to next disk. After deciding
and writing down the commands  to be programmed for each of the
six pulse activations (Function A, B, C, D, TON and TOFF),

Содержание MVP44A

Страница 1: ...tate Kn ll products sold outside of Canada and the USA may be covered by warranties provided by an authorized Kn ll distributor Please contact the distributor in the country that the Kn ll product was...

Страница 2: ...urn off and on together and share infrared signals page connect to door chimes connect to external controllers etc 8 Cooling fan Fans maximize system performance and helps to avoid earlyprotectionsyst...

Страница 3: ...d to4ohmloadsmayoccasionallyshutdownduetooverloading Never connect the MVP44a to 2 ohm loads TheMVP44ahasacoolingfantoincreaselongtermpoweroutput and reliability continued 14 3 possible in the sequenc...

Страница 4: ...commands on each of its four banks If more than 10 different IR commands are to be stored use bank 2 3 and 4 to store the sequence commands and bank one positions 1 6 to execute the sequences 1 Write...

Страница 5: ...e 590 00 and the MVP44a The 590 00 can learn up to 16 different commands on each of its four banks If more than 10 different IR commands are being stored use bank 2 3 and 4 to store the sequence comma...

Страница 6: ...the keypads are not working properly or not controlling at all Check the MR60 dip switch settings wiring layout and crimp as well as bank connections very carefully MR60 1 2 3 4 MVP44a Activation The...

Страница 7: ...drycontactclosureofeachoftheMVP44a sfour functions power on TON and power off TOFF to an IR macro sequence of up to 10 commands each The 590 00 power supply is shipped with the 590 00 Power to the 590...

Страница 8: ...our function selection buttons Three bar volume level indicators blinks at min or max Volume up and down this room only or whole house when FNC selected MR60 keypad functions OFF FNC MUTE 3 4 1 2 DN U...

Отзывы: