Congratulations and thank you for choosing the Knöll

MVP44a power amplifier. The MVP44a is designed to meet

the amplifier needs of custom installed multi-zone systems

where high quality sound is a specific requirement as well

as ease of installation and operation. A six output zone

model is available, MVP64a.

Key Features

:

1.

 

Individual zone, four source selection

Each of the four rooms

can select any of the four stereo sources.

2. 

Individual mute, volume, bass, treble and balance adjustment.

Each of the four stereo channels feature adjustments for bass, treble and
balance. Individual room keypads control volume and  mute. Any keypad
can turn the whole system on or off.

3. 

Cost and size efficiency

.

 

The MVP44a consists of a total of four

stereo power amplifiers with individual volume control electronics in a 3-
1/2" enclosure. Each power amplifier channel can deliver 50 watts RMS.

4. 

Automatic protection circuitry.

 

Each MVP44a channel is

individually and fully protected against low impedance, overheating,
overloading, overvoltage and undervoltage. The protection circuitry
automatically restores the amplifier channel as soon as its parameter
returns to the safe operating area.

5. 

External trigger and functions out.

 

An 12VDC trigger output is

provided to turn other components on or off. Six function ports are
provided (connects to a 590-00) to turn on and off components via IR as
well as provide four IR commands, source from the MR60 keypads

6. 

Stackable 17" chassis.

 

The MVP44a can be stacked or placed in a

19" EIA equipment rack (requires RK-AMP kit).

7.  

Data port

For larger systems, multiple MVP44a's can operate in

tandem so all MVP44's turn off and on together and share infrared
signals, page, connect to door chimes, connect to external controllers, etc.

8. 

Cooling fan. 

Fans maximize system performance and helps to avoid

early protection system distortion.

9. 

All on and all off. 

MR60 keypads turn on any source in all rooms.

10. 

Volume level indication. 

MR60 keypads display volume level on

top three rows of buttons. FNC-MUTE level is the lowest.

11. 

All room volume up and down

 (rooms on only) via FNC button.

15

Troubleshooting

If a problem is encountered with the MVP44a, the most expedient
procedure is to locate the problem and if possible repair it before
requesting service. Be sure to carefully check other system
components such as controllers, CD players, volume controls, wiring,
speakers, etc. that may be at fault.

Problem

Action

Power indicator does

1. Check that the MVP44a is plugged in.

not light - no sound

2. Test the AC outlet with a lamp..
3. Check that the MVP44a power button is
     on (in).

Sound cuts out

1. Verify speaker impedance is 4-16 ohms.
   Changing speakers may be required.
2. Check if the MVP44a feels hot. If it's
   hot, increase cooling - see 

Installation

.

Sound is distorted

1. Turn the volume down
2. Check speakers for damage.
3. Check inputs for proper levels.
   Source output levels may need adjustment.
4. Speakers may have less than 4 ohm rating
5. If inputs are Y corded to another MVP44a
   or stereo receiver, make sure all amps are
   turned on or a MR24 buffer may be required.

MVP44a does not

1. Press any MR60 keypad "OFF" button or

turn off

   RB8 remote "POWER" button for 5 seconds.
   The MVP44a should power down and the
   MVP44a led turns orange (standby). Before
   turning the MVP44a power switch off (out)
   we suggest that the MVP44a be in standby

Speaker pops when

1. Speaker may need resistor placed across

amp turned on or off         terminal. We suggest 2k0 1/4 w resistor

   which discharges the speakers internal
   capacitor.

Содержание MVP44A

Страница 1: ...tate Kn ll products sold outside of Canada and the USA may be covered by warranties provided by an authorized Kn ll distributor Please contact the distributor in the country that the Kn ll product was...

Страница 2: ...urn off and on together and share infrared signals page connect to door chimes connect to external controllers etc 8 Cooling fan Fans maximize system performance and helps to avoid earlyprotectionsyst...

Страница 3: ...d to4ohmloadsmayoccasionallyshutdownduetooverloading Never connect the MVP44a to 2 ohm loads TheMVP44ahasacoolingfantoincreaselongtermpoweroutput and reliability continued 14 3 possible in the sequenc...

Страница 4: ...commands on each of its four banks If more than 10 different IR commands are to be stored use bank 2 3 and 4 to store the sequence commands and bank one positions 1 6 to execute the sequences 1 Write...

Страница 5: ...e 590 00 and the MVP44a The 590 00 can learn up to 16 different commands on each of its four banks If more than 10 different IR commands are being stored use bank 2 3 and 4 to store the sequence comma...

Страница 6: ...the keypads are not working properly or not controlling at all Check the MR60 dip switch settings wiring layout and crimp as well as bank connections very carefully MR60 1 2 3 4 MVP44a Activation The...

Страница 7: ...drycontactclosureofeachoftheMVP44a sfour functions power on TON and power off TOFF to an IR macro sequence of up to 10 commands each The 590 00 power supply is shipped with the 590 00 Power to the 590...

Страница 8: ...our function selection buttons Three bar volume level indicators blinks at min or max Volume up and down this room only or whole house when FNC selected MR60 keypad functions OFF FNC MUTE 3 4 1 2 DN U...