INSTALLATION

• Always ensure the wall surface is flat and smooth for optimum installation 
• Provide power to the required point of installation
• Connect to the mains supply ensuring the correct polarity is observed: L - Live (Brown), 
   E - Earth (Green/Yellow), N - Neutral (Blue), see Fig. 1 

• An earth connection must be made to the earth terminal of the socket. Use green/yellow 
  sleeving on earth conductors that are not insulated
• Check all electrical connections are secure with no loose strands of cable
• Fit the unit into a suitable wall box taking care not to compress, damage or trap any 
   cables, and secure with the screws provided
• Switch on and check for correct operation

Fig. 1

INSTALLATION & MAINTENANCE MANUAL 

ICONS: 230V, Class I 

These instructions should be read carefully and retained after installation by the end user for future reference 

and maintenance. 

These instructions should be used to aid installation of the following products: 

SN9KW / CU9KW 
SAFETY 

 

This product must be installed in accordance with the latest edition of the IEE Wiring Regulations 

(BS7671) and current Building Regulations. If in any doubt, consult a qualified electrician 

 

Please isolate mains prior to installation or maintenance 

 

Check the total load on the circuit (including when this product is fitted) does not exceed the rating of 

the circuit cable, fuse or circuit breaker 

 

Please note the IP (Ingress Protection) rating of this product when deciding the location for installation 

 

Do not overload this accessory or subject it to conditions outside its rating 

 

This product is Class I and must be earthed 

 

This product is IP20 rated 

INSTALLATION 

 

Always ensure the wall surface is flat and smooth for optimum installation  

 

Provide power to the required point of installation 

 

Connect to the mains supply ensuring the correct polarity is observed: L - Live (Brown), E - Earth 

(Green/Yellow), N - Neutral (Blue), see Fig. 1  

 

 

 

 

 

 

 

Fig. 1 

 

 

 

 

 

 

 

 

An earth connection must be made to the earth terminal of the socket. Use green/yellow sleeving on 

earth conductors that are not insulated 

 

Check all electrical connections are secure with no loose strands of cable 

 

Fit the unit into a suitable wall box taking care not to compress, damage or trap any cables, and secure 

with the screws provided 

 

Switch on and check for correct operation 

 

 