These instructions should be read carefully and retained after installation by the end user for
future reference and maintenance.
These instructions should be used to aid installation of the following products:
BF1430EMS / BF2440EMS
GENERAL INSTRUCTIONS
• This product must be installed in accordance with the latest edition of the IEE Wiring Regulations (BS7671)
and current Building Regulations. If in any doubt, consult a qualified electrician
• Please isolate mains prior to installation or maintenance
• Check the total load on the circuit (including when this luminaire is fitted) does not exceed the rating of the
circuit cable, fuse, or circuit breaker
• Please note the IP (Ingress Protection) rating of this luminaire when deciding the location for installation
• Do not overload this accessory or subject it to conditions outside its rating
• This product is Class II double insulated
• This product is IP44 rated
SAFETY
INSTALLATION
Note - Microwave sensors may not be suitable for all installations, for example enclosed spaces, as they are
able to detect movement through non-metallic surfaces like plasterboard and thin doors
• Provide power to the required point of installation (refer to BS7671 for correct cabling methods). Suitable IP
rated junction boxes should be used where required
• Remove the diffuser by turning the three diffuser clips 90° (see Fig. 1)