These instructions should be read carefully and retained after installation by the end user for 
future reference and maintenance.
These instructions should be used to aid installation of the following products:
BF1430EMS / BF2440EMS

GENERAL INSTRUCTIONS

• This product must be installed in accordance with the latest edition of the IEE Wiring Regulations (BS7671) 

and current Building Regulations. If in any doubt, consult a qualified electrician

• Please isolate mains prior to installation or maintenance
• Check the total load on the circuit (including when this luminaire is fitted) does not exceed the rating of the 

circuit cable, fuse, or circuit breaker

• Please note the IP (Ingress Protection) rating of this luminaire when deciding the location for installation
• Do not overload this accessory or subject it to conditions outside its rating
• This product is Class II double insulated 
• This product is IP44 rated

SAFETY

INSTALLATION

Note - Microwave sensors may not be suitable for all installations, for example enclosed spaces, as they are 
able to detect movement through non-metallic surfaces like plasterboard and thin doors

• Provide power to the required point of installation (refer to BS7671 for correct cabling methods). Suitable IP 

rated junction boxes should be used where required

• Remove the diffuser by turning the three diffuser clips 90° (see Fig. 1)

Содержание BF1430EMS

Страница 1: ...INSTALLATION MAINTENANCE MANUAL BF1430EMS BF2440EMS...

Страница 2: ...ed does not exceed the rating of the circuit cable fuse or circuit breaker Please note the IP Ingress Protection rating of this luminaire when deciding the location for installation Do not overload th...

Страница 3: ...he fitting Mark the location of the fixing holes and drill ensuring not to infringe with any gas water pipes or electrical cables Feed the mains cable through the rubber grommet to retain IP rating an...

Страница 4: ...ery capacity SENSOR LAYOUT The additional terminal called Slave Live SL is available to enable the sensor to power on additional luminaires A max LED load of 500W can be controlled by the sensor Adjus...

Страница 5: ...Clean the external surfaces with a damp cloth using a mild solution of detergent and warm use aggressive cleaning products or solvents which may damage the product Do not use any source of high pressu...

Страница 6: ...supply is restored after test and ensure charge indicator is illuminated Annual 3 hour duration test simulate a mains supply failure for 3 hour continuous test by operation of key switch or switching...

Страница 7: ...record sheet 230V 50Hz IP44 Class II Non Dim Ta AVJUL21 EU authorised representative SLV Group Holdings GmbH Niederkasseler Lohweg 18 Germany 40547 D sseldor...

Страница 8: ...AVSEP1_V4 ML Accessories Limited LU5 4LT www mlaccessories co uk 02 INTERNATIONAL CONTACT DETAILS INTERNAT CONTACT D 20 50 C TA...

Отзывы: