Page 8 of 20
0900455 Rev: F (06/02)
DISPLAY WINDOW
The display window shows various information about the dispenser during normal operation (i.e. when the Remote
Control is not being programmed). The following examples will illustrate:
When there is no pump activity, the display window shows the
display name and current formula (or “RELAY MODE” if used).
If using Drain Mode, the drain count will appear during the
formula and will return to the normal display when the formula is
finished.
DISPLAY NAME
FORMULA 01
When a pump delay time is active, the display window shows the
count-down in seconds.
FORMULA 01
P1 DLY 023 SEC
Shows total load counts for all formulas (or if using RELAY
mode). Individual formula load counts can also be viewed. See
page 7 for details on viewing load counts.
LOAD COUNT
00000 LOADS
When the bleach defeat function is enabled, the bottom line of the
display will flash alternately between NO BLEACH, and the
current formula name (or “RELAY MODE” if used). See page 7 for
details on how bleach defeat works.
DISPLAY NAME
NO BLEACH
When a pump is running, the display shows the count-down as a
volume (with your selected unit of measure) or as a time, in
seconds. See DISPENSER SETUP menu for details on choosing
volume or time display.
FORMULA 01
P1 VOL 017.0 OZS
ACCESS CODES
When working with a Multi-Flow system, there are two levels of protection for the system. The “main”, or programmer
level, allows the programmer to enter all of the menus and functions of the Multi-Flow system. The “user” level allows
only a few basic on-site functions without the possibility of changing programmed information.
All systems are shipped from the factory with the main and user access codes set at 000. Changing the access
codes is explained later in this manual. To get started, press ENTER (from the main display window).
If the “user” access code is entered, menu availability is limited to only the functions in the USER MENU. All other
menu headings are still visible in the display window, however they cannot be entered.
Use the SCROLL and INC/DEC buttons (not necessary if code
has not yet been changed from factory default of 000) to input the
access code, then press ENTER. If the “main” access code is
entered, all functions of the system are then accessible.
ACCESS CODE 000
THEN PRESS ENTER