Page 14 of 20
0900455 Rev: F (06/02)
CALIBRATE
PUMPS
2
This selection allows you to prime pumps. Use INC/DEC to
choose the pump number, then press ENTER to start pump.
Press ENTER again to stop pump. Press MENU
to continue.
PRIME PUMP 1
ENT = START/STOP
This selection allows you to choose “volume” or “time” pump
calibration — see the following notes. Use INC/DEC to make your
selection, then press ENTER. Press MENU
to continue.
CALIBRATE=VOLUME
INC/DEC ENTER
VOLUME: Pump flow rates are set by actually running the pump
and dispensing product. This allows the system to calculate true
flow rates. Use a large container with volume markings, such as a
beaker or graduated cylinder, for the calibration steps below.
TIME: Setting pump flow rates is not necessary. Pumps simply run
for a specific time as programmed in each formula. See the
FORMULA SETTINGS menu for more details.
This selection appears if you chose “volume” calibration.
Choose the pump you wish to calibrate using the INC/
DEC buttons, then press MENU
to continue.
CALIBRATE P 1
INC/DEC
Use SCROLL and INC/DEC to set a volume amount you
wish to calibrate with (4 oz, 6 oz, 12 oz, etc). Ensure that
the pump is primed, then position your container below
the pump output. Press ENTER to start the pump. When
the container is filled to the volume you specified, press
ENTER again to stop the pump. The flow rate is
automatically calculated and you will see the following...
DISPENSE 000 OZS
ENT = START/STOP
To view existing flow rates, use INC/DEC to choose the
pump (ensure that the “cursor” is blinking on the pump
number) then press ENTER . If you know the exact flow
rate and want to enter it manually, use SCROLL and
INC/DEC to establish the volume (ensure that the
“cursor” is blinking on the volume) and press ENTER.
NOTE: The cursor position determines whether data is
read from or written to memory.
FLOW RATES/MIN.
P-1 =000.0 OZS
Press MENU
to calibrate other pumps. If desired, you can get to
the above display without having to run pumps by simply pressing
MENU
when entering CALIBRATE PUMPS menu.