65
Output data
Output
P 42000 Dx
TRMS-nnnn
0 … 20 mA, 4 ... 20 mA and/or 0 …
10 V to customer requirement,
switchable
P 42100 Dx
TRMS-nnnn
0 … 20 mA, 4 ... 20 mA or
0 … 10 V
fixed to customer requirement
Displacement
Up to 100 % as default
Load
With output current
≤ 12 V (600 ohms at 20 mA)
With output voltage
≤ 10 mA (1000 ohms at 10 V)
Residual ripple
< 10 mVrms
Response
Gain error
< 0.5 % full scale
Gain error for sinusoidal input signals (crest factor √2) in the
frequency range 45 … 65 Hz
Response T90
< 150 msec rising
< 300 msec falling
Influential factors
(additional error)
Frequency 40 … 1000 Hz< 1% meas.val. (typ. 0.5%)
Crest factor 1 … 3
< 0.5 % meas.val.
(non-sinusoidal signals)
Crest factor < 3 … 5
< 1% meas.val.
VariTrans
®
P 42000 D2 / D3 TRMS
Specifications (continued)