ProLine P16800
40
12.7 Switching Output
Switching output (solid state relay): SW
Fault contact, normally closed contact (NC), opens in
case of fault
U
SW max
/ I
SW max
33.6 V / 100 mA
Internal voltage drop
< 0.2 V at 20 mA
U
SW
with open switch without external switching voltage
> 1 V
I
SW
with open switch
Approx. 130 μA
Reference potential
GND
Fault response time
< 1 s
12.8 Transmission Behavior
Rated frequency range
0
…
25 kHz
Duty cycle of speed sensor signals to be transmitted
20 %
…
80 %
Response time
t
99
< 1 ms
Response time difference in both channels
< 10 μs
Frequency division,
factory set
P168*****/2*: 1:1, 2:1, switchable
P168*****/4*: 1:1, 4:1, switchable
P168*****/8*: 1:1, 8:1, switchable
Maximum duty cycle deviation output signal to input signal
without frequency division
± 10 %
Duty cycle of output signal with frequency division indepen-
dent of input signal duty cycle
50 % ± 10 %
Standstill detection
f < 1 Hz ± 0.3 Hz
Reference voltage generation for standstill signaling
U
out
= 7.2 V
True zero speed
The output level follows the input level (valid for 1:1
transmission)
Response in the event of input frequency jump
Immediate transmission with specified latency period
Direction of travel signal DOT (without SIL),
only P16840
Δφ = φ2 - φ1; Δ φ > 0
→
High; Δφ < 0
→
Low