Specifications NF 1.60 DCB-B / DCB-4B
Motor variant
DCB-B
DCB-B
DCB-4B
Supply voltage [V]
12
24
10..26.4
Power consumption [W]
10.2
10.6
10.9
Max. I load [A]
0.85
0.44
1.1..0.39
Protection class [-]
IP50
Weight
1)
[g]
260
Tab. 6
Specifications NF 1.60 DC
Motor voltage
12V
24V
Power consumption [W]
10
Max. I load [A]
0.8
0.4
Max. permissible current
consumption [A]
1.4
0.71
Protection class [-]
IP00
Weight
1)
[g]
320
Tab. 7
1)
The weight may differ slightly from the stated value, depending on the
version.
Electrostatic sensitive components (ESD)
Other parameters
Parameter
Value
Permissible ambient temperature range
[°C]
+ 5 to + 40
Permissible media temperature range [°C] + 5 to + 80
Permissible kinematic viscosity of the
media [cSt]
≤ 150
Tab. 8