3.  Safety 

 

Observe the safety precautions in Chapters  
6. Installation and connection and 7. Operation. 

 

The pumps are built according to the generally recognised rules of 
technology and in accordance with the pertinent occupational 
safety and accident prevention regulations. Nevertheless, potential 
dangers during use can result in injuries to the user or others, or in 
damage to the pump or other property. 

Only use the pumps when they are in a good technical and proper 
working order, in accordance with their intended use, observing the 
safety advice within the Operating and Installation Instructions, at 
all times. 

Make sure that only trained and instructed personnel or specially 
trained personnel work on the pumps. This especially applies to 
assembly, connection and servicing work. 

Make sure that the personnel has read and understood the Operat-
ing and Installation Instructions, and in particular the "Safety" 
chapter. 

Always ensure adherence to all pertinent accident prevention and 
safety regulations when working on and operating the pump. 

When transferring dangerous media, observe the safety regula-
tions for handling such media. 

Always ensure adherence to all information stickers on the pumps, 
such as flow direction arrows and type plates, and keep stickers in 
a legible condition. 

All replacement parts should be properly stored and disposed of in 
accordance with the applicable environmental protection regula-
tions. Ensure adherence to the pertinent national and international 
regulations. This applies especially to parts contaminated with toxic 
substances. 

Dispose of all packaging in an environmentally-appropriate 
manner. The packaging materials are recyclable. 

Dispose of end-of-life equipment in an environmentally 
friendly manner. Use appropriate waste collection systems 
for the disposal of end-of-life equipment. Used pumps 
contain valuable recyclable materials. 

 

 

 

Personnel 

Working in a 

safety-conscious manner 

Handling dangerous media 

Notes 

Environmental protection 

Disposal 

Содержание NF 1.30

Страница 1: ...is a country specific designation with no technical relevance Contents Page 1 About this document 2 2 Use 3 3 Safety 4 4 Technical data 6 5 Assembly and function 8 6 Installation and connection 9 7 Op...

Страница 2: ...ntial danger It also indicates the possible consequences of failure to observe the warning The signal word e g Warn ing indicates the level of danger Here you will see actions for avoiding the danger...

Страница 3: ...he compatibility of the materials of the pump head pump housing diaphragm and valves with the medium The temperature of the medium must lie within the permissible temperature range see Chapter 4 The t...

Страница 4: ...and understood the Operat ing and Installation Instructions and in particular the Safety chapter Always ensure adherence to all pertinent accident prevention and safety regulations when working on and...

Страница 5: ...ted machinery may not be commissioned until such time as it has been determined that the machine in which the partly completed machinery is to be assem bled conforms to the provisions of the Machinery...

Страница 6: ...type KT stands for Assembly Material1 Pump head PP Valve socket PP FFKM Sealing washer FFKM Diaphragm PTFE Tab 2 1 according to DIN ISO 1629 and 1043 1 The pump head comprises an intermediate plate a...

Страница 7: ...head material and the hoses hose connectors used Hydraulic connections Parameter Value Recommended hose size ID mm OD mm 4 6 Tab 5 Specifications NF 1 30 DCG Motor voltage 12V 24V Power consumption W...

Страница 8: ...Working chamber 4 Diaphragm 5 Eccentric 6 Connecting rod 7 Pump drive Fig 2 Pump assembly The diaphragm liquid pumps are based on reciprocating displace ment pump technology The elastic diaphragm 4 i...

Страница 9: ...3 Mounting dimensions NF 1 30 DCG Make sure that the installation location is dry and the pump is protected against water in the form of rain spray splashes and drips Protect the pump against dust Pr...

Страница 10: ...red motor cable black motor cable 6 3 Hydraulic connection Only connect components to the pump that are designed to handle the hydraulic data of the pump see Chapter 4 Technical data Only use hoses th...

Страница 11: ...d contact with flammable materials WARNING Danger of bursting of the fluid system due to overpressure The pump builds up pressure A closed system can cause the max permitted operating pressure to be e...

Страница 12: ...and can also be regulated to some extent For details see Chapter 4 Technical data Duty cycle short cycle operation KNF pumps are designed for continuous operation Short start and stop cycles may adve...

Страница 13: ...e contact your local KNF partner for further in formation www knf com Switching off the pump KNF recommends if transferring aggressive liquids the pump should be flushed thoroughly prior to switch off...

Страница 14: ...gerous substances in the pump Depending on the medium transferred caustic burns or poisoning are possible Wear protective clothing if necessary e g pro tective gloves Flush the pump with a neutral liq...

Страница 15: ...ten it securely Press the edges of the diaphragm all around Ensure the sealing washers 4 are dust free and place them in the centre of the valve socket seat of the intermediate plate 6 one sealing was...

Страница 16: ...inal Operating and Installation Instructions CAUTION Escaping liquid After assembly the pump may not be leak tight due to incorrect assembly damaged or soiled seal faces or other reasons Run the pump...

Страница 17: ...ket and seals see Section 8 2 3 Replace pump Tab 10 Pump is not priming Cause Remedy Suction side of pump not con nected Connect the suction side of the pump Liquid in the container is too low Fill co...

Страница 18: ...mp Clean the pump head install suction side filter if required Spare Parts and Accessories see Chapter 8 2 Viscosity of the transferred medium is too high Contact KNF Incorrect interchange of pres sur...

Страница 19: ...sories Spare Parts Spare Part Item Number per pump Order No Delta PT screw 30x30 1 4 160308 FFKM sealing washer 4 4 060463 PP FFKM valve socket 5 2 060186 PVDF FFKM valve socket 5 2 060161 PTFE diaphr...

Страница 20: ...ions 11 Return of the pump KNF undertakes to repair the pump only under the condition that the customer provides a certificate of the pumped medium and cleaning of the pump For this purpose please fol...

Страница 21: ...Diaphragm Liquid Pump NF 1 30 For your notes KNF Flodos AG BA_NF1 30_EN_04_067674 docx Translation of original Operating and Installation Instructions 21...

Страница 22: ...KNF worldwide Please find your local KNF partners at www knf com...

Отзывы: