Diaphragm Liquid Pump NF 1.30
For your notes
KNF Flodos AG BA_NF1.30_EN_04_067674.docx
Translation of original Operating and Installation Instructions
13
Switching on the pump
In order to ensure that the pump starts every time, make sure
that counterpressure is reduced to an acceptable level before
start-up. This should also be done during operation after a brief
power cut. Please contact your local KNF partner for further in-
formation (www.knf.com).
Switching off the pump
KNF recommends: if transferring aggressive liquids, the pump
should be flushed thoroughly prior to switch off (see Section
8.2.1), as this will help to lengthen the service life of the dia-
phragm.
Restore the system to normal atmospheric pressure (release
hydraulic pressure in pump).
Flow rate NF 1.30
Fig. 5: Flow rate of the NF 1.30
CAUTION
Overpressure on the suction side causes medi-
um to flow through the switched-off pump
Take steps to ensure that this cannot produce a
hazardous situation.