Diaphragm liquid pump NF 100
Use
KNF Flodos BA_NF100_EN_10_067676.docx
Translation of original Operating and Installation Instructions
3
2. Use
2.1. Intended use
The pumps are intended for transferring and metering liquids.
Owner's responsibility
Only install and operate the pumps under the operating parameters
and conditions described in Chapter 4, Technical data.
Only completely installed pumps may be taken into service.
Before transferring or metering a medium, check whether the
medium can be transferred danger-free in the specific application
case.
Before using a medium, check the compatibility of the materials of
the pump head, pump housing, diaphragm and valves with the
medium.
The temperature of the medium must lie within the permissible
temperature range (see Chapter 4).
The transferred medium should not contain particles as these can
prevent the pump from working correctly. If this cannot be guaran-
teed, a filter < 100
m with sufficiently large filter area must be
used upstream of the pump.
The .51 versions of our diaphragm liquid pump range have been
certified by NSF according to the standard NSF/ANSI 169 and are
therefore suitable for use with foodstuffs without any restrictions.
All materials used have been checked through a series of toxico-
logical tests. In order to ensure that the food grade quality is main-
tained, NSF will carry out a yearly audit checking our certified
products.
Only the pumps marked with ".51" are NSF certified. and contain a
defined material combination that also has a FDA certificate of
conformity.
NSF: National Sanitary Foundation
FDA: Food and Drug Administration
ANSI: American National Standard Institute
* Pumps with other customer-specific certified material combinations are
available on request.
Operating parameters and
conditions
Requirements for
transferred medium
.51* version – version with food
grade approval