Technical data
Diaphragm pump N96_DC-B-M
12
Translation of Original Operating and Installation Instruction, English, KNF 316836-316838 06/22
Electrical data
Parameter
Unit
Value
KN version
Value
KT/AT/ST version
Voltage
[V]
24
24
Frequency
[Hz]
-
-
Power P
1
[W]
23
19
Max. permissible mains
voltage fluctuations
[%]
± 10
± 10
Motor protection class
IP20
IP20
Rated current consump-
tion
[A]
1.05
0.9
Tab.9 Electrical data
The motor controller has a current limit of max. 2.5 A RMS. In the
event of an error, the power of the motor is limited to prevent the
current limit from being exceeded.
Weight
Pump type
Unit
Value
N96K_DC-B-M
[kg]
0.6
N96STDC-B-M
[kg]
0.9
N96ATDC-B-M
[kg]
0.65
Tab.10 Weight
Other parameters
Parameter
Unit
Value
Permissible ambient
temperature [°C / °F]
[°C / °F]
+ 5 / + 41 to see Fig. 1
0 / +32 if non-condensing (frost-free)
Permissible media tem-
perature [°C / °F]
[°C / °F]
See Fig. 2
Dimensions
See Fig. 5, Chapter
Highest permissible rel-
ative air humidity of the
environment
80% for temperatures up to 31°C /
86°F, decreasing linearly to 50% at
40°C / 104°F.
Maximum installation al-
titude [m / ft above sea
level]
[m / ft
above sea
level]
2000 / 6562
Gas tightness* of the
pump head (leak rate)
[mbar l/s]
< 6 x 10
-3
Protection class of
pump
IP20
Starts against
- Vacuum [mbar abs]
- Pressure [bar rel* /
psig]
KN
KT / AT / ST
Permissible ambi-
ent temperature
[°C / °F]
[°C / °F]
130
2.5 / 36.4
Tab.11 Other parameters
*The gas tightness of the pump head is no longer ensured after the pump head is
opened or after replacing diaphragms and valve plates. A leak test can be used to