Installation and connection
Diaphragm pump N96_DC-B-M
18
Translation of Original Operating and Installation Instruction, English, KNF 316836-316838 06/22
Fig.5 Mounting dimensions of pump series N96DC-B-M
Cooling air supply
WARNING
Danger of burning on hot surfaces
Hot surfaces could occur if the pump overheats.
à
When installing the pump, make sure that
sufficient cooling air infeed and discharge is
ensured.
Immediate environment of the
hot pump parts
à
During installation, make sure that no combustible or thermally de-
formable objects are positioned in the immediate proximity of the hot
pump parts (head, drive).
Installation location
à
Make sure that the installation location is dry and that the pump is pro-
tected from rain, spray water, splash water, dripping water and other
contaminants.
à
Make sure the installation location allows access for periodic mainte-
nance and inspection.
The IP protection class of the pump motor is specified on the type
plate.
à
Install the pump at the highest point in the system to prevent conden-
sate from collecting in the pump head.
à
Protect the pump from dust.
à
Protect the pump from vibration and impact.