Operation
Diaphragm Vacuum Pump N 828 / N 838
38
Translation of original Operating and Installation Instructions, english, KNF 121249-121517 09/19
Symbol
Interpretation
Meaning
E
Announcement of
completion
0 command cannot be
completed
1 command completed
? command unclear
S
Status message
For service only
V
Version number
e.g. 01.018
ni
Actual motor speed
Value [min
-1
]
ns
Nominal motor speed Value [min
-1
]
nl
Minimum nominal
motor speed
Value [min
-1
]
nh
Maximum nominal
motor speed
Value [min
-1
]
ii
Operating current of
the motor
Value [mA]
ti
Temperature of the
motor controller
Value [°C]
ei
Fault status
16 bit value
Tab. 16: Symbols
The symbols represent the ASCII codes of sequences of digits any
length. The controller processes input values only as whole num-
bers (integers).
Interface level
See p. 28
for pin assignment of the motor controller’s commu-
nication plug.
Parameter
Value
Rx KNF MBLC
Low: 0V…0.9V
High: 4.2V…5.2V
Tx KNF MBLC
Low: 0V…0.6V
High: 4.5V…5.2V
Tab. 17