Assembly and function
Operating Instructions LIQUIPORT EN
24
KNF Flodos | BA_LIQUIPORT_EN_11_153820.docx | Translation of original operating instructions, English
4.
Assembly and function
4.1 Metering pump assembly
1
On/Off button
2
Control knob
3
Flow rate indicator
4
Standby indicator
5
External indicator
6
Inlet
7
Pump head
8
Outlet
9
Power supply plug
10
External actuation plug (RC
version only)
Fig. 9: Diaphragm pump
4.2 Operating principle
1
Outlet valve
2
Inlet valve
3
Working chamber
4
Diaphragm
5
Eccentric
6
Connecting rod
7
Pump drive
Fig. 10: Pump assembly
The diaphragm liquid pumps are based on reciprocating displacement
pump technology. The elastic diaphragm (
4
) is moved up and down by
the eccentric (
5
) and the connecting rod (
6
). In the downward stroke it
aspirates the medium to be transferred via the inlet valve (
2
). In the
upward stroke the diaphragm pushes the medium out of the pump
head via the outlet valve (
1
). The diaphragm hermetically seals off the
working chamber (
3
) from the pump drive (
7
).
Содержание LIQUIPORT 1.100