5.2 Preparing for dismantling
1. Rinse the pump with a suitable neutralizing liquid and make
sure that there are no dangerous substances left in the pump
(see warnings above).
2. Pump the unit empty.
3. Disconnect electrical connections.
4. Remove hoses from pump head.
Qty
Tools
1
Torx screwdriver T30
1
Slotted screwdriver size 0
1
Allen key size 4mm
Table 1
5.3 Dismantling the motor
To clean the pump or replace the elastomer parts, the motor does
not necessarily have to be dismantled. In this case, continue with
Section 5.5.
1. Undo the four screws (
1
).
2. Carefully remove the motor from the pump housing.
3. Remove the O-ring (
3
) from the motor flange (
2
).
5.4 Mounting the motor
1. Insert the O-ring (
3
) into the motor flange (
2
).
Place the motor on the pump housing. Make sure that the
coupling parts engage properly and that the star-shaped damp-
ing element is installed.
Tighten the four screws (
1
) to 2.5 Nm.
Tools
Figure 1: Motor