background image

For your own safety, read the manual and always observe the 
warnings and safety information on the device and in the 
manual.

Technical Support: 

Phone:       +49 30 809727-111 (9-17h, Central European Time)
Fax: 

+49 30 8015010

E-Mail:

  [email protected]

Languages: German, English

Publisher:

KNAUER Wissenschaftliche Geräte GmbH
Hegauer Weg 38
D-14163 Berlin
Phone:     +49 30 809727-0
Fax:          +49 30 8015010
Internet:   

www.knauer.net

E-Mail:     

 [email protected]

Version information:

 

Article  number:  V6879

 

Version number: 1.

3

The information in this document is subject to change without prior 
notice. 

For latest version of the manual, check our website:

http://www.knauer.net/en/Support/User-Manuals

Copyright:

© KNAUER Wissenschaftliche Geräte GmbH 2018. All rights reserved.
AZURA® is a registered trademark of KNAUER Wissenschaftliche 

Geräte GmbH.

Printed in Germany on environmentally 
friendly paper from sustainable forests.

Содержание AZURA HPLC

Страница 1: ...HPLC Air sensor Supplement Document no V6879...

Страница 2: ...Phone 49 30 809727 0 Fax 49 30 8015010 Internet www knauer net E Mail info knauer net Version information Article number V6879 Version number 1 3 The information in this document is subject to change...

Страница 3: ...erve the warnings and safety information on the device and in the supplement NOTE Technical data are subject to change without notice Please check our website for latest updates and changes Intended U...

Страница 4: ...a computer The airsensor is controlled by KNAUER software PurityChrom which supports up to 4 airsensors Upon detecting air you can program differ ent actions The purification can either be stopped or...

Страница 5: ...detection on the tubing then start the installation NOTE The number of the airsensor corresponds to the num ber on the cable that is being used If you have more than one airsensor connect the other am...

Страница 6: ...y for approximately 3 s Integrating into PurityChrom You can program the software to either start or stop the system after an air bubble has been detected NOTE You have to choose the Gameport Input 1...

Страница 7: ...Process and figures 1 Open the PurityChrom Setup 2 Go to the register Communication 3 In the section Control Inputs you can make the necessary changes 4 To stop the system change the settings as follo...

Страница 8: ...ort Input 1 2 3 or 4 which equals the airsensor number Process Figures 1 To open the Time Control Editor press the button 2 Go to the register Threshold 3 Choose the Gameport Input 1 from the dropdown...

Страница 9: ...tivate the function Wait for Input Signal at a particular time during the method NOTE Make sure that the functions succeeding the function Wait for Input Signal start with a delay of 0 01 s NOTE Do no...

Страница 10: ...nsert to confirm the changes 7 After reaching the function Wait for Input Signal the run pauses until the end of sample After the signal the run contin ues automatically Name Order number Airsensor fo...

Страница 11: ...tions online https www knauer net en Support User manuals KNAUER Wissenschaftliche Ger te GmbH Hegauer Weg 38 14163 Berlin Phone 49 30 809727 0 Fax 49 30 8015010 E Mail info knauer net Internet www kn...