Battery voltage correction:
The battery voltage correction is used to compensate for the opening loss time of an injector. The
opening loss time is dependent on the battery voltage and may vary from 1.8 ms at 8V to 0.4 ms at
16V. When battery voltage correction is not applied, the mix will weaken when the battery voltage
decreases, with the risk of engine damage. In this table this effect can be compensated for by
matching the injector opening time to the battery voltage. The correction values are indicated in
ms per injection. For instance, 0.68 ms will be added to the duration of injection when the battery
voltage is 12.6V. The table is suitable for injectors with a resistance of 12Ω - 15Ω.
Atmospheric pressure correction:
If you use an internal or separate atmospheric pressure sensor, you can set correction percentages
for ambient pressure levels in this table.