STE-6012/6016 Room Temperature Sensors 

Application Guide, AN0412C Rev. B

KMC Controls, Inc.

19476 Industrial Drive

New Paris, IN 46553

574.831.5250

www.kmccontrols.com

[email protected]

Accessories

HMO-6036 

Universal Backplate, Almond

HMO-6036W 

Universal Backplate, White

KMD-569

x

 

STE-6016 to Controller Cable with 

RJ-45 to RJ-11 Connectors (KMD-

569

3

 = 25 ft.; KMD-569

4

 = 50 ft.; 

KMD-569

5

 = 75 ft.)

KMD-5624 

PC Data Port (EIA-485) Cable

KMD-5576 

EIA-485 to USB Communicator

SP-001 

Flat Blade and Hex End Screw

-

driver

© 2013 KMC Controls, Inc.  

AN0412C Rev. B

Specifications

Connections

 

Clamp (screw-type) terminals 

or modular RJ-45 jack (see 

Models chart)

Material

 

Flame-retardant plastic, light 

almond or white

Weight

 

Approx. 1.25 oz. (35 grams)

Sensor

Type 

Type II thermistor

Accuracy 

± 0.36° F (± 0.20° C)

Resistance 

10,000 ohms

 

@ 77° F (25° C)

NTC 

4.37%/° C @ 25° C

Dissipation Constant  2 mW/° C
Temp. Reading 

0–5 VDC voltage output

Front Buttons

 

Two momentary push buttons 

that signal override condition, 

adjust setpoint, toggle ° C or 

F, and calibrate temperature 

reading

Power Requirements 7.5 VDC

 (10.4 mA max. cur

-

rent draw) for unoccupied/

setback mode or 

12 VDC

 (9.7 

mA) for occupied/normal 

mode

Approvals

 

CE compliant

Environmental Limits

Display 

35° to 90° F (2° to 32° C)

Operating 

34° to 125° F (1.1° to 51.6° C)

Shipping 

–40° to 140° F (–40° to 60° C)

Humidity 

0 to 95% RH non-condensing

Important Notices

The material in this document is for information 

purposes only. 

The contents and the product it 

describes are subject to change without notice.

 

KMC Controls, Inc. makes no representations or 

warranties with respect to this document. In no event 

shall KMC Controls, Inc. be liable for any damages, 

direct or incidental, arising out of or related to the 

use of this document.

Содержание STE-6012

Страница 1: ...ottom of the STE 6016 case is an EIA 485 formerly RS 485 computer port This port provides a temporary connection to the digital network for network setup or troubleshooting To use the port to connect to a computer a means of converting the EIA 485 signal to a USB or EIA 232 formerly RS 232 signal will be needed The exact connection depends on the computer and the opera tor workstation software See...

Страница 2: ...Controller Configuration section Fahrenheit Celsius Display Selection The STE 6012 6016 has an LCD display for showing room temperature and setpoint The display can be toggled between Fahrenheit the default and Celsius scales by performing the following procedure NOTE Doing this erases any stored calibration offset value see below and returns the calibration to the default setting 1 Press and hold...

Страница 3: ...ied the sensor is in setback unoccupied mode with 12 VDC applied the sensor is in normal occupied mode Pressing the Down button momentarily sends 0 VDC to the controller for a SENSORON signal on terminal C or orange wire pressing the Up button sends greater than 5 VDC for a SENSOROFF signal Pressing a button raises or lowers the setpoint voltage When in unoccupied mode pressing either button selec...

Страница 4: ...ield and or Name field 11 Click Autorun 12 Click End Edit 13 Click Yes for Send Update Notification Now 14 Click once in the column 15 Type in program lines see the following example NOTE This is only an example Details need to fit the controller configuration 10 REM STE 6012 6016 OVERRIDE 20 REM AI1 IS STE 6012 6016 TEMPERATURE SENSOR INPUT 30 REM BV3 IS OCCUPIED UNOCCUPIED ON OFF MODE 40 IF NOT ...

Страница 5: ...SE GOTO 190 170 STOP VAR4 180 OUT3 12 WAIT 0 00 02 190 RETURN 8 Click Send 9 Click OK 10 Click Close 11 Click OK NOTE See also the Override section below and Setpoint Voltage Input and Variable on page 6 NOTE For another sample application of program ming override timers adapt the informa tion in the Application Note AN0504F Programming Override Timers section of the Digital Designer s Guide SP 02...

Страница 6: ...nu select Control Setpoint Variables 11 Click Edit 12 Type in a name in the Description field and or Label field 13 Click Units which opens the Configure Variables screen 14 Select Type Analog if it is not the default 15 Select Degrees Fahrenheit or Celsius 16 Set Format to 0 17 Click OK 18 Click End Edit 19 Click OK NOTE See also Control Basic Setpoint Calculation and Override on page 5 Setpoint ...

Страница 7: ...field and or Label field 4 Select Units 5 Select Type Analog if it is not the default 6 Select 0 10 Volts 7 Leave the rest of defaults 8 Click OK 9 Click End Edit 10 Click OK BAC A1616BC BACnet Building Controller Tables and Jumpers Select the 0 12 VDC jumper position for the corre sponding inputs See the Installation section of the BAC A1616ABC Building Controller Installation and Operation Guide...

Страница 8: ...users or returns Exposed to air flow through the conduit from leaks in plenum ducts put plumber s putty or similar material inside the conduit to block air flow Setpoint Input 1 In the desired Analog Input setup screen of the web page interface select Device Type of 0 5 volts 2 Select the Lookup Table for the STE 6012 Setpoint BBC table 3 For the Fahrenheit scale the multiplier is 1 8 and the offs...

Страница 9: ...curacy 0 36 F 0 20 C Resistance 10 000 ohms 77 F 25 C NTC 4 37 C 25 C Dissipation Constant 2 mW C Temp Reading 0 5 VDC voltage output Front Buttons Two momentary push buttons that signal override condition adjust setpoint toggle C or F and calibrate temperature reading Power Requirements7 5 VDC 10 4 mA max cur rent draw for unoccupied setback mode or 12 VDC 9 7 mA for occupied normal mode Approval...

Отзывы: