background image

4IN. x 36IN. BELT/6IN. DISC SANDER

OWNER’S MANUAL

3 of 7

USE TABLE WITH THE BELT

• Thread the Stud into the Belt Housing.
• Position the Table over the Stud and Bracket. Secure the 

Table using the two Knobs.

• Thread the Locking Handle through the Table and in to the 

Bracket

• Using a combination square, set the table perpendicular to 

the belt and secure in position. If necessary, set the Pointer 
to 0º .

GROUNDING INSTRUCTIONS

WARNING: Improper connection of equipment ground-
ing conductor can result in the risk of electrical shock. 

Equipment should be grounded while in use to protect 
operator from electrical shock. 

• Check with a qualified electrician if grounding instructions 

are not understood or if in doubt as to whether the tool is 
properly grounded. 

• This tool is equipped with an approved 3-conductor cord 

rated at 150V and a 3-prong grounding type plug (Figure 7) 
for your protection against shock hazards. 

• Grounding plug should be plugged directly into a properly 

installed and grounded 3- prong grounding-type receptacle 
as shown. 

Do not remove or alter grounding prong in any manner. In the 
event of a malfunction or breakdown, grounding provides a 
path of least resistance for electrical shock. 

WARNING: Do not permit fingers to touch the terminals 
of plug when installing or removing from outlet.

 

• Plug must be plugged into matching outlet that is properly 

installed and grounded in accordance with all local codes 
and ordinances. Do not modify plug provided. If it will not fit 
in outlet, have proper outlet installed by a qualified electri-
cian. 

• Inspect tool cords periodically, and if damaged, have 

repaired by an authorized service facility. 

• Where a 2-prong wall receptacle is encountered, it must be 

replaced with a properly grounded 3-prong receptacle 
installed in accordance with National Electric Code and local 
codes and ordinances. 

WARNING: This work should be performed by a quali-
fied electrician. 

A temporary 3-prong to 2-prong grounding adapter (as shown) 
is available for connecting plugs to a two pole outlet if it is 
properly grounded.
• Do not use a 3-prong to 2-prong grounding adapter unless 

permitted by local and national codes and ordinances. (A 
3-prong to 2-prong grounding adapter is not permitted in 
Canada.) 
Where permitted, the rigid green tab or terminal on the side 
of the adapter must be securely connected to a permanent 
electrical ground such as a properly grounded water pipe, a 
properly grounded outlet box or a properly grounded wire system. 

• Many cover plate screws, water pipes and outlet boxes are 

not properly grounded. To ensure proper ground, grounding 
means must be tested by a qualified electrician. 

GUIDELINES FOR EXTENSION CORDS

• 

Use a proper extension cord.

 Make sure the extension cord 

is in good condition. When using an extension cord, be sure 
to use one heavy enough to carry the current your product 
will draw. An undersized cord will cause a drop in line 
voltage, resulting in loss of power and possible overheating.

• 

Be sure the extension cord is properly wired and in good 
condition.

 Always replace a damaged extension cord or have 

it repaired by a qualified person before using it. Protect your 
extension cords from sharp objects, excessive heat and 
damp or wet areas.

OPERATING INSTRUCTIONS

CONTROLS AND ADJUSTMENTS

SANDING SAFETY TIPS

WARNING:

 Operation of any power tool can result in 

foreign objects being thrown into the eyes, which can 

result in severe eye damage. Always wear safety goggles 
complying with United States ANSI Z87.1 (shown on package) 
before commencing power tool operation. 

CAUTION:

 Always observe following safety precautions. 

Horizontal to Vertical

Pivot Socket Bolt

Belt Tracking

Adjusting Knob (35)

Belt Tension Lever

Table Angle Scale

Switch 

Содержание 426246

Страница 1: ...OWNER S MANUAL WARNING Read carefully and understand RULES FOR SAFE OPERATION and instructions before operating Failure to follow the safety rules and other basic safety precautions may result in seri...

Страница 2: ...hers in the work area from debris such as chips and sparks Provide barriers or shields as needed Keep children out of workplace Make workshop childproof Use padlocks master switches or remove switch k...

Страница 3: ...laten or work table UNPACKAGING WARNING Do not operate machine until completely assembled Do not operate machine until you have completely read and understood this manual When unpacking check for ship...

Страница 4: ...cle installed in accordance with National Electric Code and local codes and ordinances WARNING This work should be performed by a quali fied electrician A temporary 3 prong to 2 prong grounding adapte...

Страница 5: ...ASIVE BELT TRACKING Turn the Belt Sander on if the Belt slides off either Roller the Belt Tracking needs to be adjusted to center on idler drums If belt moves to the left turn tracking nut to the righ...

Страница 6: ...s the Drive Drum to tension the Belt Check the Tracking Assemble in reverse order ABBRASIVEDISC REPLACEMENT Remove table assembly Remove disc cover by loosening and removing four screws Remove old abr...

Страница 7: ...or or wiring problem The V Belt is too tight You re sanding with too much pressure on the stock The Belt is not tracking properly it goes either left side or right side of idler roller The Abrasive Di...

Страница 8: ...201 Pulley Set Screw Retaining Ring Retaining Ring Ball Bearing Base Cover Socket Head Bolt Flat Washer Vertical Stop Socket Head Bolt Socket Head Bolt Flat Head Screw Label Stud Pivot Pivot Stop Sock...

Страница 9: ...silica from bricks and cement and other masonry products Arsenic and chromium from chemically treated lumber Your risk from these exposures varies depending on how often you do this type of work To re...

Отзывы: