background image

 

independant Fix 

Instructions for Use

 

Revision 01 

1

 

General Information 

1.1

 

Manufacturer 

We thank you for buying one of our products. 
This product bears the CE mark. This means that it meets the basic requirements on the safety and the 
performance of medical devices set forth by the respective applicable European regulations. 
We are the manufacturer of this product: 

 

LM Medical Division s.r.l. 

Via Brigate Alpine 9 
25036 Palazzolo sull’Oglio 
Brescia – Italy 
Phone +39 030 7453357  

 

1.2

 

Hotline 

Should you have any questions on how to handle the device or product or use it for clinical applications, 
please do not hesitate to contact the Product Management: 
Phone:  +49 7461 706-345 
Fax: 

+49 7461 706-190 

 

In case of technical questions and questions regarding maintenance contracts and training, please contact 
our Martin Service Center: 
Phone:  +49 7461 706-343 
Fax: 

+49 7461 706-484 

E-mail:  [email protected] 

 

 

To answer your technical questions as efficiently as possible, our service technicians require the serial 
number of the product. Therefore, please have this number at hand when contacting our hotline. The 
serial number is indicated on the rating plate. 

 

1.3

 

Terms & Acronyms 

Designation 

Description 

UDA 

Medical Supply Units 

MD 

Medical Device 

EMC 

Electromagnetic Compatibility 

 

Содержание independant Fix Bridge

Страница 1: ...ront Cover English independant Fix Bridge independant Fix Ceiling independant Fix Wall Instructions for Use 0051 90 577 52 10 Revision 01 Date of Release 2020 11 www klsmartin com...

Страница 2: ...ould result in death or serious injury DANGER Indicates a situation which if not avoided will result in death or serious injury Instructions for Use Serial number Date of manufacture Manufacturer Dist...

Страница 3: ...pplicable SOCKET 1 SOCKET 2 Socket identification as per electrical diagram where applicable xxxVA lighting Power consumption of each light Correct Configuration Key required Inlay shape diameter Clic...

Страница 4: ...ion 9 5 Screw Torques 10 6 Functioning 11 7 General and Technical Features 16 7 1 General Features 16 7 2 Technical Specification 16 8 Cleaning and Maintenance 18 8 1 Required Maintenance 18 8 2 Recom...

Страница 5: ...dle the device or product or use it for clinical applications please do not hesitate to contact the Product Management Phone 49 7461 706 345 Fax 49 7461 706 190 In case of technical questions and ques...

Страница 6: ...DA installation must be done following indication listed on manufacturer installation manual Electrical connection must be done following the manufacturer electrical scheme Gas outlet distribuiton mus...

Страница 7: ...d on the plate Please don t connect adapters between the device s electrical sockets and plugs Risk of injury due to system parts falling down Please don t overload UDA s max load listed on the relate...

Страница 8: ...other equipment 3 Intended Use The pendant models Indepedant Fix are manufactured for medical use areas only in order to allow Electrical current flow Data nurse calling system phone PC network Medica...

Страница 9: ...independant Fix Instructions for Use Revision 01 9 4 Configuration independant Fix Bridge independant Fix Wall independant Fix Ceiling...

Страница 10: ...independant Fix Instructions for Use 10 Revision 01 5 Screw Torques Dimension Torques M5 7 Nm M6 12 Nm M8 30 Nm...

Страница 11: ...independant Fix Instructions for Use Revision 01 11 6 Functioning...

Страница 12: ...independant Fix Instructions for Use 12 Revision 01...

Страница 13: ...independant Fix Instructions for Use Revision 01 13...

Страница 14: ...independant Fix Instructions for Use 14 Revision 01...

Страница 15: ...independant Fix Instructions for Use Revision 01 15...

Страница 16: ...est For each unit the following tests are performed Ground impedance protection conform to standard 8 6 laid down by IEC EN 60601 1 Standard leakage current and dielectric strength measure conform to...

Страница 17: ...component parts lists calibration instructions or any other useful information that technical assistance may requires in order to repair component s replaceable parts Manufacturer registered office an...

Страница 18: ...EN ISO 7396 1 and EN ISO 7396 2 8 2 Recommended Maintenance We recommend to check the following list every 6 months Correct operation of the brake system LEDs movement and braking correct Possible mo...

Страница 19: ...o not overlap more than 5 devices and do not place them vertically In case of irreparable damages or end of life equipment the device must be disposed following the existing rules If the user does not...

Страница 20: ...es Independent Fix is easy to clean due to smooth surfaces Is Independent Fix easy to maintain No maintenance is needed except for gas implants please refer to this manual Does Independent Fl Fix ex i...

Страница 21: ...ve humidity should be at least 30 Electrical fast transient 2 kV phase i Earth 1 kv phase i phase i 2 kV common mode 1 kv differential mode Voltage quality should be like a typical hospital environmen...

Страница 22: ...tance in metres Radiowave radiated power 3 V m 80 MHz to 2 GHz 3 V m P d 35 0 80 MHz to 800 MHz P d 7 0 800 MHz to 1 GHz P d 33 2 1 GHz to 2 5 GHz where P is the maximum output power rating of the tra...

Страница 23: ...or Use Revision 01 23 12 Maintenance Log Book Serial number MD Official distributor Required maintenance Frequency Registration Name Date Inspection of flexible gas hoses Each 6 months Replacing of fl...

Страница 24: ...sia Tel 7 499 792 76 19 russia klsmartin com KLS Martin Taiwan Ltd Taipei Taiwan Tel 886 2 2325 3169 taiwan klsmartin com Gebr der Martin GmbH Co KG Dubai United Arab Emirates Tel 971 4 454 16 55 midd...