TROUBLESHOOTING
INSUFFICIENT DRAUGHT.
DIFFICULT FLUE GAS EVACUATION.
DISTRIBUTION OF THE FLUE GAS IN THE INDOOR ENVIRONMENT.
ELEMENTS TO CHECK
ORIGIN
External air vent
Inexistent;
Gate valve closed;
Accidental obstruction;
Insufficient section.
Air vent (pipe)
Insufficient section.
Flow regulator
Closed or badly regulated
Hood gate valve
Closed or badly regulated.
Wood
Excessive humidity.
Flue
Hood fitting/flue gas channel
Insufficient section;
Insufficient height;
Accidental obstructions;
Periodical cleaning not performed;
Heat insulation or insulation insufficient or
inexistent;
Use of unsuitable materials;
Heat insulation or insulation absent or insufficient;
Inadequate section (square or rectangular) in
incorrect dimensioning;
Narrowing or presence of obstacles to the flow of
flue gas;
Accidental obstructions;
Infiltrations of parasite air due to the use of
materials non-impermeable to gas and liquids;
Insufficient height.
Chimney
The outlet height in reflow zone;
Vicinity or approach to other chimneys;
Vicinity of obstacles, both natural and artificial;
Obstruction ( Example: birds nests);
Inadequate chimney pot shape;
Insufficient emission section.