39
Boiling
If for any reason (power cut, a pump fault, too much wood, etc…), the
water in the fireplace body reaches boiling point, carry out the
following operations immediately,
IN SPITE THAT THE FIREPLACE
HEATING SYSTEM GUARANTEES ABSOLUTE SAFETY:
Open the fireplace heating system smoke damper;
Open the DHW cock and leave the water to run until the
temperature in the fireplace body drops
(only for models
connected to the DHW plant);
Open the hatches or the vertical sliding door;
Close the primary air front slots completely
After having ascertained the reason for the high temperature, wait
for every thing to go back to normal (temperature below 60°C)
check on the control unit that the water level LED is not on and, if
necessary, open the cold water load from the float.
Anti-freeze protection
In intensely cold periods it is good practice that the heating system
remains running. In the case of prolonged absence, anti-freeze must
be added to the heating water or the system must be completely
emptied.
In a system subject to being emptied frequently it is indispensable that
filling is performed with water that has been appropriately treated to
eliminate hardness that can lead to lime scale deposits.
Functioning principle
The fireplace heating system is just a wood-burning boiler made in a
way to be able to be inserted into a traditional fireplace.
You therefore have the pleasure of seeing the flame through the
ceramic glass like in a normal fireplace, but the radiators in the home
are also heated and DHW is supplied for all of the family.
The fireplace heating system can be integrated into an appliance that
is already installed (gas boiler, diesel oil boiler or wood-burning etc...)
or can function as a unique source of heating for the home.
Содержание TKR 35