14
ASSEMBLY
Positioning
The initial phase for the best installation of the fireplace heating
system is to determine its optimal location; regarding this the
following data needs to be taken into account:
Possibility of creating an external air vent;
Possibility of creating a straight flue and possibly coaxial at
the fireplace heating system outlet;
Possibility of creating piping necessary to discharge
boiling;
Proximity to the main liquid collector and /or the boiler if
one already exists);
Proximity or ease of connection to the water system.
Once the best location for the appliance is determined, it is
possible to position the fireplace heating system following the
indications below.
The appliance must be installed on a floor with suitable load
capacity. If the existing building does not fulfil this requirement
appropriate measures (e.g. load distribution plate) must be
taken.
The minimum safety distance from inflammable materials must
be at least 300 mm from the fireplace heating system.
Appliance installation must guarantee easy access for cleaning
the appliance itself, the gas pipes and the flue.
The air extraction devices must not be used in the same room as
the appliance, unless an adequate ventilation air supply is
envisioned.