INTRODUCTION 

Important safety instructions 

Please read these instructions before installing and using the product. 

   
-

 

The installation and initial start-up of the appliance must be performed by skilled personnel trained in the relevant 

safety standards. They will be responsible for the definitive installation of the appliance and its proper operation. 

KLOVER srl shall not be held liable if these precautions are not observed. 

-

 

During installation of the appliance, all local regulations - including those referring to national and European 

Standards - must be observed. 

-

 

Connect the flue gas outlet to a flue with the specifications described in the “Flue and its connection” section of this 

User guide. 

-

 

The appliance is not suitable for installation on a shared flue system. 

-

 

If the flue should catch fire, use appropriate fire extinguishing equipment or call the fire brigade. 

-

 

Connect the product to an earthed power socket. Avoid using sockets controlled by switches or automatic timers. 

-

 

Do not use the power supply cable if damaged or worn. 

-

 

If a multiple socket is used, make sure that the total voltage of the connected devices does not exceed the rated 

voltage for the socket. Also make sure that the total voltage of all the devices connected to the socket does not 

exceed the maximum permitted level. 

-

 

Do not use flammable substances to clean the appliance or its parts. 

-

 

Do not leave flammable containers and substances in the place where the appliance is installed. 

-

 

The appliance works exclusively with wood pellets and only with the hearth door shut. 

-

 

NEVER open the door of the appliance during normal operation.  

-

 

The use of poor quality pellets or any other material can damage the appliance operation, voiding the warranty and 

exempting the manufacturer from all liability.  

-

 

Do not use the appliance as an incinerator or for any use other than that for which it was designed. 

-

 

Do not use fuels other than those recommended. 

-

 

Do not use liquid fuels. 

-

 

The appliance, and its outer surfaces in particular, become very hot to the touch during operation; handle with 

caution in order to avoid burns. 

-

 

Only use original spare parts recommended by the manufacturer. 

-

 

Do not make any unauthorised modifications to the appliance. 

-

 

Do not touch the hot components of the product (ceramic glass, flue pipe) during normal operation. 

-

 

Never touch the appliance if you are barefoot and/or if you have wet or damp parts of the body. 

-

 

Use the appropriate button to switch off the electrical panel. Do not disconnect the power supply cable while the 

appliance is operating. 

-

 

During the ignition phase and normal operation of the appliance, maintain the necessary safety distance and do not 
remain standing in front of it. 

-

 

Keep children away from the appliance when it is running since they could get burned by touching its hot 

components. 

-

 

Do not leave the packaging elements within reach of children or unassisted disabled persons. 

-

 

Children and inexperienced people must not be allowed to use the appliance. 

-

 

Do not use the appliance in ways other than those indicated in this user guide.  

-

 

The appliance is designed for indoor use only. 

-

 

This user guide constitutes an integral part of the appliance. If the product is sold to another user, this manual must 

be passed on to the new owner. 

-

 

The Klover pellet products are not suitable for use in smokeless zones. 

 
KLOVER S.R.L. DECLINES ALL LIABILITY IN CASE OF ACCIDENTS DUE TO FAILURE TO COMPLY WITH THE 

SPECIFICATIONS OF THIS MANUAL. 

 

KLOVER S.R.L. DECLINES ALL LIABILITY DUE TO INCORRECT USE OF THE PRODUCT BY THE USER, 

UNAUTHORISED MODIFICATION AND/OR REPAIRS, AND USE OF NON-ORIGINAL SPARE PARTS OR SPARE 

PARTS NOT SPECIFICALLY DESIGNED FOR USE ON THIS PRODUCT MODEL. 
KLOVER S.R.L. SHALL NOT BE HELD LIABLE FOR THE STOVE'S INSTALLATION. THE INSTALLER IS THE 

SOLE PARTY RESPONSIBLE FOR THIS OPERATION AND IS ALSO ENTRUSTED WITH CHECKING THE FLUE, 

Содержание STAR 14

Страница 1: ...ENGLISH STAR 14 Pellet boiler stove INSTALLATION USE AND MAINTENANCE USEFUL TIPS...

Страница 2: ......

Страница 3: ...e A1 Distance from combustible material 200 mm Fuel spillage risk Compliant Emission of combustion products Nominal power Reduced power CO at 13 of O2 0 010 CO at 13 of O2 0 037 Effective temperature...

Страница 4: ...ONTROL OF ANY COUPLED BOILER 14 CONNECTION TO THE ROOM THERMOSTAT 15 HYDRAULIC CONNECTION 15 THE DISPLAY 16 THE MENU 18 INITIAL START UP 22 FILLING THE SYSTEM FOR THE FIRST TIME 22 PELLET LOADING AND...

Страница 5: ...nce and its operation instructions for proper installation basic maintenance and control points which must be periodically performed furthermore it contains practical advice which helps to obtain maxi...

Страница 6: ...ncinerator or for any use other than that for which it was designed Do not use fuels other than those recommended Do not use liquid fuels The appliance and its outer surfaces in particular become very...

Страница 7: ...By laws and other regulations that affect the installation of the appliance The Building Regulations requirements can be met by adopting the relevant recommendations given in British Standards BS 8303...

Страница 8: ...the heating system Expansion tank 8 l with pre load 1 bar Safety valve calibrated 2 5 bar REAR TECHNICAL COMPARTMENT Manual air vent valve with key and rubber pipe Return pipe connection of the heati...

Страница 9: ...STAR 14 PELLET BOILER STOVE 6 EN Rev 2 1 Overall dimensions...

Страница 10: ...STOVE 7 EN Rev 2 1 Connections data sheet Description of connections M System Delivery 3 4 F R System Return 3 4 M X Safety valve drain 1 2 F A Intake pipe 43 mm S Flue gas outlet 80 mm M E Electricit...

Страница 11: ...037 Power consumption min max Watt 25 300 Nominal voltage V 220 Nominal frequency Hz 50 Expansion vessel litres preloading bar 8 1 Maximum operating recommended pressure bar 2 5 1 5 Flue pipe diamete...

Страница 12: ...must be compliant with some international standards such as EN14961 2 DIN 51731 and O NORM M7135 which establish minimum values for quality checks on pellets To facilitate the right choice of the comb...

Страница 13: ...d technical assistance centre where it is necessary to disconnect the device from the system will not be recognised under warranty as described in chapter Warranty Conditions External air intake Durin...

Страница 14: ...onditions of use refer to UNI 9615 It must be made of suitable materials capable of withstanding normal mechanical stress heat and the effects of combustion gases and condensate if any It must go upwa...

Страница 15: ...d 70 C IT IS MANDATORY TO HAVE AN INITIAL VERTICAL SECTION OF AT LEAST 1 5 MT IN ORDER TO GUARANTEE CORRECT FLUE GAS DISCHARGE Every direction change must be carried out with a T shaped fitting and in...

Страница 16: ...TRICAL CONNECTION The electric connection must only be performed by qualified staff in compliance with all general and local safety standards Check that the power supply voltage and frequency correspo...

Страница 17: ...standard boiler when the heating circulating pump of the pellet appliance starts up so as to avoid having two boilers operating simultaneously on the same system The coupled boiler is however always...

Страница 18: ...pump of the system is forcedly switched on to ensure the disposal of excessive heat thus avoiding the reaching of high temperatures of the water in the boiler For this reason it is recommended that th...

Страница 19: ...s any liability for damages caused due to incorrect assembly THE DISPLAY The appliance s operating mode is displayed on the console After turning on the menu it is possible to choose from many types o...

Страница 20: ...display when setting or programming operating parameters Set 1 2 3 4 5 6 The INPUT area shows the entered programming values The MENU LEVEL area shows the current parameter menu level The DIALOGUE ar...

Страница 21: ...ing power of the appliance Menu mode Moves you to the next menu item Programming mode Moves you to the next submenu item storing the changes made 6 Increase power 3 Working off Increases the working p...

Страница 22: ...enable disable and set the programmable thermostat weekly program functions MENU LEVEL SELECTION MEANING POSSIBLE VALUES 02 03 01 CHRONO WEEKLY Enable disable the weekly programme ON OFF The weekly pr...

Страница 23: ...TION MEANING POSSIBLE VALUES 02 04 01 CHRONO WEEK END Enable disable the weekend programme ON OFF 02 04 02 START 1 WEEK END Turn on time of the first programme Time OFF 02 04 03 STOP 1 WEEK END Turn o...

Страница 24: ...rol the appliance with the boiler temperature only disable the room sensor on the Remote control Stove settings menu Enable room sensor OFF The room sensor is automatically disabled if no external Rem...

Страница 25: ...ied or when it is filled for the first time Warning once the operation has been completed before switching on the appliance you should empty the accumulation of pellets deposited inside the brazier Me...

Страница 26: ...arranty Ignition cycle Pressing button 4 ON OFF for a few seconds allows you to start the ignition cycle After a while the display shows START and the flue gas intake device and ignition resistance sw...

Страница 27: ...rential set on Pr43 set as default at 5 C in other words if Temperature H2O SET H2O Pr43 The appliance automatically starts up again if the following condition occurs The temperature falls below the t...

Страница 28: ...set temperature the appliance will perform the same procedure as with the opening of the room thermostat See Connection to the room thermostat Remote control The following table shows the function of...

Страница 29: ...s not been done and if you have not filled the entire boiler body and system with water in order not to compromise its duration The noise level of the appliance is emphasised if the pellet container i...

Страница 30: ...ure sensor AL 3 HOT TEMP Flue gas over temperature When flue gas temperature is higher than 260 C Before displaying the alarm or when flue gas maximum temperature is reached Pr14 the display shows HOT...

Страница 31: ...ns use the personal protection devices specified in Directive 89 391 EEC The required cleaning frequency depends on the type and quality of the pellets used The schedule indicated below may therefore...

Страница 32: ...prevent damaging the vacuum cleaner We do not recommend the use of normal vacuum cleaners Non routine cleaning The extraordinary cleaning of the appliance must be done at least every 15 days so as to...

Страница 33: ...TOVE 30 EN Rev 2 1 Dismount the 4 flue diverters 2 on the right and 2 on the left placed on the combustion chamber sides figure 6 e 7 and scrape the internal walls with a spatula removing any deposit...

Страница 34: ...e boiler body Then reassemble the 4 flue diverters its bottom and the ash box To ensure correct operation it is necessary to remove the sawdust deposited on the base of the tank Figure 10 at least onc...

Страница 35: ...aranteeing correct operation optimal heat performance and durability of the device Therefore qualified staff should check the appliance at least once a year at the beginning of the season You must per...

Страница 36: ...4 11 Automatic re ignition after blackout BLACKOUT IGNITION Seconds 0 60 30 Pr49 M 9 4 12 Pellet level sensor enable PELLET RESERVE On off On off Off Pr50 M 9 4 13 Pump start for over temperature saf...

Страница 37: ...in output 1 working mode NOT USED AIR 1 SPEED Volt 65 225 65 Pr24 M 9 6 24 Exchanger 1 motor speed in output 2 working mode NOT USED AIR 2 SPEED Volt 65 225 65 Pr25 M 9 6 25 Exchanger 1 motor speed in...

Страница 38: ...ALT MANUAL RESET THERMOSTAT FUSE 4A 5X20 CN12 CN10 PCB L023 CN14 CONNECTOR FOR BOOTLOADER CONNECTION WIRES 220 V FOR CONTROLLING COUPLED BOILER IF CONNECTED AUX BLUE RED P M FOR THE ELECTRICAL CONNEC...

Страница 39: ...where it is not proved that their condition is due to a manufacturing defect rather than the effects of wear electric and electronic parts in which the malfunction can be traced to a non compliant el...

Страница 40: ...Cod CS IST ST14 EN FP KLOVER Srl Via A Volta 8 37047 San Bonifacio VR P IVA 02324280235 www klover it...

Отзывы: