STAR 14 PELLET BOILER STOVE
10
EN - Rev. 2.1
The unit must be installed on a floor with a suitable load capacity. If the existing building does not fulfil this requirement
appropriate measures (e.g. load distribution plate) must be taken.
The minimum safety distance from flammable materials must be at least 200 mm from the sides and back of the
appliance.
Relocating the appliance should not be done by forcing on the handle, glass or ceramics.
The installation must guarantee easy access for cleaning the appliance, the flue gas exhaust pipes and the flue, and any
subsequent maintenance operation by the Authorised technical assistance centre.
Once you have found the best location for the appliance, position it following the instructions given below.
Spaces around and above the appliance
The figure below shows the minimum distances from walls or other not-easily-removable furniture, that need to be taken
into consideration when positioning the appliance.
REAR WALL
SI
D
E
WA
LL
SI
D
E
WA
LL
50 cm
50 cm
15 cm
Any shelves or false ceilings mounted above the appliance must be at least 100 cm away from the top part of it.
Furniture and movable objects must be positioned at least 15 cm from the side surfaces of the appliance; these objects
must be moved when performing maintenance on the appliance.
Protect all structures that can catch fire against the radiated heat of the fire.
Any extra intervention by the Authorised technical assistance centre, where it is necessary to disconnect the
device from the system, will not be recognised under warranty as described in chapter
“Warranty Conditions”
.
External air intake
During operation, the appliance takes in air from the environment in which it is installed; It is therefore essential that this
air is replaced through an external air vent. The absence of the air vent may affect the flue draught and therefore the
combustion and the safety of the appliance.
Therefore it is mandatory to install an external air vent with a minimum completely free passage of at least 80 cm
2
(round hole with minimum diameter of 15 cm protected with a special fixed large mesh grid).
If the wall behind the appliance is on the outside, we recommend you make the hole near it at about 20 cm above the
ground
(see example in Fig. A)
.
If it is not possible to put an air vent in the wall behind the appliance, make a hole in a perimeter wall in the room where it
is installed. If it not possible to put the external air vent in the same room as where the appliance is installed, this hole
can be made in an adjoining room as long as this room communicates permanently, by means of a transit hole (15 cm
minimum diameter).
The hole must be protected externally with a fixed grille. The protective grille must be checked periodically to ensure that
it is not obstructed, thereby impeding the passage of air. Therefore keep the air vents clear of obstructions.
The UNI 10683 Standard FORBIDS the drawing of combustion air from garages, warehouses storing combustible
materials, or from business premises with a fire hazard.