17
CS.ECO-TFT.IST-1-EN / Rev 1.0
ENGLISH
o
Sub-menu 4.7.1
–
ACTIVATION TYPE
Allows for setting how to control activation of the smoke chamber cleaner:
➢
ON
= cleaner always active.
Whenever the appliance is switched on, automatic cleaning of the smoke chamber is activated, regardless of the time.
➢
TIME
= cleaner active with pre-defined time slot.
Whenever the appliance is switched on within the set time slot
(see Sub-menu 4.7.2
–
TURBULATORS ON TIME / 4.7.3
–
TURBULATORS OFF TIME)
, the smoke chamber is cleaned automatically. If the appliance is always switched on outside the set
time slot, automatic cleaning is carried out at the first available power-on after the time set in
Pr144
has elapsed.
o
Sub-menu 4.7.2
–
TURBULATORS ON TIME
With sub-menu 4.7.1
–
ACTIVATION TYPE = TIME it allows for setting the daily start time of the slot within which automatic
cleaning is allowed.
o
Sub-menu 4.7.3
–
TURBULATORS OFF TIME
With sub-menu 4.7.1
–
ACTIVATION TYPE = TIME it allows for setting the daily end time of the slot within which automatic cleaning
is allowed.
5
–
INSTALLER CALIBRATIONS
Allows for accessing all data reserved for the system configurations. Access is protected by an
access key “
P5
”.
The menu is reserved for expert users only; access by non-expert users can cause serious damage to the appliance, objects and the environment, as
well as personal injuries. Klover declines all responsibility deriving from improper calibration of these values.
-
Sub-menu 5.1
–
PELLET CALIBRATION
Allows for making a limited calibration of the pellet load in the modes indicated in the following table:
MENU
MEANING
SETTABLE VALUES
PELLET
CALIBRATION
By increasing the value by a single unit, the pellet load is increased by about 2%.
-4 / +4
By reducing the value by a single unit, the pellet load is reduced by about 2%.
-
Sub-menu 5.2
–
CHIMNEY CALIBRATION
Allows for making a limited calibration of the flue gas extractor speed according to the modes indicated in the following table:
MENU
MEANING
SETTABLE VALUES
CHIMNEY
CALIBRATION
Increasing the value by a single unit increases the flue-gas extractor speed
(and thus the inclusion of combustion air) by roughly 3%.
-4 / +4
Decreasing the value by a single unit decreases the flue-gas extractor speed
(and thus the inclusion of combustion air) by roughly 3%.
-
Sub-menu 5.3
–
PLANT TYPE
Allows for configuring the appliance according to the type of system to which it has been connected to
(see
“System configuration”
)
.
5.4
5.5
5.1
5.2
5.3