29
EN
G
LISH
“Various calibrations” (Menu M8 –
2)
(Firmware H02_250117)
Parameter
Description
Display writing
Measurement
Value field
Database o1
Pr38
Re-ignition block
RE-IGNITION BLOCK
Minutes
0
–
10
5
Pr39
Flue gas extractor switch-off time
EXTRACTOR OFF
MINUTES
Minutes
0
–
20
10
Pr40
Pre-loading time in ignition
IGNITION PRE-LOADING
Seconds
0
–
255
0
Pr41
Stand-by time after pre-loading
STAND-BY AFTER PRE-
LOADING
Seconds
0
–
255
0
Pr42
Extractor speed in pre-loading phase
EXTRACTOR PRE-
LOADING
RPM
600
–
2800
2800
Pr43
“SET AMBIENT”
ON temperature
hysteresis
DELTA AUTO
°C
0.0
–
15.0
2,0
Pr44
Economy switch-off delay (timer after
reaching
“SET AMBIENT”
)
DELAY AUTO
Minutes
2
–
120
2
Pr45
Power change delay
POWER CHANGE
Seconds
0
–
60
30
Pr46
Enabling of remote control
ENABLE REMOTE
On
–
off
On
–
off
OFF
Pr47
Keypad block enabling
KEYS BLOCK-EN
On
–
off
On
–
off
OFF
Pr48
Automatic re-ignition after blackout
BLACKOUT
Seconds
0
–
60
30
Pr49
Room sensor calibration
SENSOR OFF-SET
°C
- 9
–
9
0
Pr50
Preheating time
PRE-HEAT TIME
Seconds
0
–
360
300
Pr51
Extractor speed in preheating time
PRE-HEAT GASSPEED
RPM
500
–
2800
2800
“Pellet type” (Menu M8 –
3)
(Firmware H02_250117)
Parameter
Description
Display writing
Measurement
Value field
Database o1
Pr54
Pellet loading percentage at the various
working powers
PELLET LOADING
-
- 9
–
9
0
“Chimney type” (Menu M8 –
4)
(Firmware H02_250117)
Parameter
Description
Display writing
Measurement
Value field
Database o1
Pr55
Flue gas extraction speed percentage
at the various working powers
EXTRACTOR CHIMNEY
-
- 9
–
9
0
Содержание DEA ECO 12