background image

 

31 

 

EN

G

LISH

 

WARRANTY 

The warranty takes effect from the date of purchase of the product, which must be demonstrated by 

means of a delivery document or other document issued by the seller. The document must be shown to 

the Technical Assistance Centre, if required. 

-

 

A copy of the warranty coupon sent to KLOVER s.r.l. must be stored together with the purchase 

document received. 

-

 

KLOVER s.r.l. declines all liability for any accidents due to failure to observe the specifications contained 

in the use and maintenance manual accompanying the device. 

-

 

Furthermore, KLOVER s.r.l. declines all liability deriving from improper use of the product by the user, 

unauthorised modifications and/or repairs, and the use of non-original spare parts or spare parts not 

designed for use on this product model. 

 

KLOVER s.r.l. guarantees the quality of materials, good construction and functionality of the 

product for a period of 2 years, under the following conditions: 

 

1.

 

On its own unquestionable judgement, the device evidencing material or construction faults will be 

repaired or replaced; with the exception of all costs relating to transport, restoration (hydraulic 

disassembly and assembly operations, any masonry works and any other necessary intervention) and 

accessory materials. 

2.

 

The warranty does not cover: 

-    ceramic glass and ceramic-majolica and/or varnished steel linings, as they are very fragile so they 

can get accidentally damaged; 

-    any part made of ceramic-majolica evidencing altered colour shades, pitting, cracks, shading and 

slight dimensional variations, as these cannot be regarded as product defects but features deriving 

from the handmade processing; 

-    the cast iron brazier, the cast iron grid and plate, smoke deflector or flame arresters, gaskets, fuses 

or batteries inside the device's electronic system and any other removable component, if it is proved 

that their condition is due to a manufacturing defect rather than the effects of wear; 

-    electric and electronic parts, in which the malfunction can be traced to a non-conforming electrical 

connection, natural disaster (lightning, electrical discharges, etc.) and variation or voltage other than 

the nominal voltage; 

-    any parameter calibration intervention due to the type of fuel or installation of the device. 

3.

 

The replaced components are guaranteed for the remaining period of the warranty, starting from the date 

of purchase and/or for a period not exceeding 6 months. 

4.

 

The use of poor-quality wood pellets or other fuel could damage the components of the device thereby 

voiding the relevant warranty and the manufacturer's liability. Therefore, we recommend using the fuel 

type indicated in our specifications. 

5.

 

Incorrect installation carried out by unqualified personnel, tampering with, failure to comply with the 

instructions contained in this "use and maintenance manual" and those regarding “workmanlike 
installation” shall void any warranty rights; the s

ame applies to damages deriving from external factors. 

At all events, any compensation for direct or indirect damages is excluded, regardless of the nature and 

cause of the damages. 

6.

 

Please bear in mind that the goods travel under the customer’s responsi

bility, even if delivered carriage 

free, therefore we shall not be held liable for any damages due to loading and unloading operations, 

accidental knocks, storage in unsuitable places, etc. 

7.

 

The boiler unit of water-based products only connected to a heating and/or sanitary water system is 

guaranteed for 5 years, at the above-mentioned conditions. 

8.

 

The warranty is only valid if the duly filled-in warranty coupon - clearly legible in all its parts - is mailed in 

a closed envelope. 

 

The competent law court for settling any disputes is the Court of Verona.  

 

Содержание DEA ECO 12

Страница 1: ...STUFA A PELLET DEA ECO 12 INSTALLAZIONE USO E MANUNTENZIONE CONSIGLI UTILI ITALIANO FRAN AIS ENGLISH ESPA OL Cod CS IST SE12 Rev 1 3 S R L Main Revision 1 3 FPH_supplement 001...

Страница 2: ...9 FLUE AND CONNECTION TO THE LATTER STACK 10 ELECTRICAL CONNECTION 13 CLEANING AND MAINTENANCE 14 PRECAUTIONS BEFORE CLEANING 14 ROUTINE CLEANING 14 EXTRAORDINARY CLEANING 15 CLEANING THE CERAMIC GLA...

Страница 3: ...or proper installation basic maintenance and control points which must be performed regularly furthermore it contains practical advice for obtaining maximum performance from the stove with minimum fue...

Страница 4: ...for which it was designed Do not use different fuels to those recommended Do not use liquid fuels The device especially its external surfaces becomes very hot to the touch during operation handle it...

Страница 5: ...s operational limits Regularly perform all maintenance activities Authorise expert and competent people to use the stove Failure to comply with the requirements of this guide shall automatically void...

Страница 6: ...E GUIDE ONE WARRANTY COUPON ONE POWER SUPPLY CABLE This manual is an integral part of the machine if the stove is sold it must be handed down to the new owner AMBIENT TEMPERATURE SENSOR PELLET TANK SE...

Страница 7: ...6 ENGLISH Connections data sheet S 80 mm M FLUE GAS OUTLET A 33 mm AIR EXTRACTION DEVICE E SWITCH WITH ELECTRIC CABLE CONNECTION REAR VIEW...

Страница 8: ...imum draught Pa 12 1 12 1 Pellet tank capacity Kg 27 Pellet min max hourly consumption Kg h 2 81 0 51 Operating autonomy at minimum maximum output h 10 53 Flue pipe diameter mm 80 Nominal voltage V 22...

Страница 9: ...conformity to international standards such as EN14961 2 DIN 51731 and O NORM M7135 are indicated on the packaging The packages are intact since pellets tend to absorb humidity Humidity not only reduce...

Страница 10: ...measurements to be observed when positioning the stove in relation to the walls REAR WALL SIDE WALL SIDE WALL 50 cm 50 cm 10 cm Any shelves or false ceilings mounted above the stove must be at least 5...

Страница 11: ...imney is essential to the efficient operation of a Klover appliance The chimney should be designed and constructed according to these instructions and relevant regulations including Building Regulatio...

Страница 12: ...and initial vertical rise The flue system should run as vertically as possible as any deviations off the vertical can adversely affect the draw 45 is the maximum off vertical angle than may be used N...

Страница 13: ...deciding whether a particular chimney design will provide sufficient draught The outlet from the chimney should be above the roof of the building in accordance with the provisions of Building Regulati...

Страница 14: ...rom parts subject to high temperatures During the final wiring of the circuit only use components with a suitable electrical protection rating KLOVER srl declines all responsibility for injury to pers...

Страница 15: ...of the pellets used The schedule indicated below may therefore vary Any problem affecting the stove caused by lack of cleaning will not be covered by the warranty Routine cleaning The stove requires...

Страница 16: ...equipped with a fine mesh filter in order to prevent part of the ash from being spilled and thus damaging the cleaner itself Extraordinary cleaning To be performed at least every 30 days Perform routi...

Страница 17: ...chamber sides and scrape the internal walls with a spatula removing any deposit Aspirare il deposito all interno utilizzando un aspiracenere idoneo e poi riposizionare il fondo ed il cassetto cenere...

Страница 18: ...events whenever necessary It is important to check for any obstructions in the flue before switching the stove on following long periods of idleness If cleaning is not performed the operation of the s...

Страница 19: ...n when at least one switch on off programme is active SCREW FEED the LED is on when the pellet loading gearmotor switches on FAN the LED is on when the hot air fan is active ON OFF the LED flashes dur...

Страница 20: ...RAMMING Increases the value of the parameter 3 OFF WORK MODE Ignites or switches off the stove when pressed for 2 seconds ALARM BLOCK Releases alarm MENU Allows for accessing the selected menu MENU PR...

Страница 21: ...ramme Stop Prog 1 Switch off time first weekly programme Mon Prog 1 Enable first programme Monday Tue Prog 1 Enable first programme Tuesday Wed Prog 1 Enable first programme Wednesday Thu Prog 1 Enabl...

Страница 22: ...R Sub menu M2 1 ENABLE TIMER Allows for globally enabling and disabling all programmable thermostat functions Sub menu M2 2 DAILY PROGRAMME Allows for enabling disabling and setting the daily programm...

Страница 23: ...amme Time OFF Mon Prog 3 Enable third programme Monday ON OFF Tue Prog 3 Enable third programme Tuesday ON OFF Wed Prog 3 Enable third programme Wednesday ON OFF Thu Prog 3 Enable third programme Thur...

Страница 24: ...M6 FIRST LOADING Allows for performing pellet pre loading for 90 with the stove off and cold Start the function with button 2 and stop with button 3 It may be useful in case the stove is switched on...

Страница 25: ...resistance to get hot enough before the loading of the pellet onto the crucible The appliance goes into FLAME STAND BY after the pre load phase starting to load the pellet onto the crucible at regula...

Страница 26: ...LEANING for a pre defined duration see parameters table ATTENTION If you do not wish to control the stove with an ambient temperature it is advisable to set the SET TEMPERATURE value to MAN Manual If...

Страница 27: ...e maximum safety temperature is reached inside the tank with resulting intervention of the safety thermostat with manual rearm In this case the stove must be restarted by rearming the safety thermosta...

Страница 28: ...thus the stove will not switch on If the flue gets obstructed during normal operation the stove will burn all the pellets in the brazier before activating the DEPRESS FAILURE alarm the pellet tank go...

Страница 29: ...se P1 SCREW FEED Seconds 0 1 4 0 0 8 Pr07 Screw feed gearmotor ON time in power 5 work phase P5 SCREW FEED Seconds 0 1 4 0 2 3 Pr08 Flue gas extraction speed in brazier cleaning phase EXTRACTOR CLEANI...

Страница 30: ...nutes 2 120 2 Pr45 Power change delay POWER CHANGE Seconds 0 60 30 Pr46 Enabling of remote control ENABLE REMOTE On off On off OFF Pr47 Keypad block enabling KEYS BLOCK EN On off On off OFF Pr48 Autom...

Страница 31: ...TOR T A ROOM THERMOSTAT CONNECTION FITTING TO ENSURE CORRECT OPERATION DO NOT REVERSE THE POLARITY OF THE WIRES RED BLUE PROGRAMMABLE THERMOSTAT BATTERY TYPE CR2032 3Volts PHASE NEUTRAL EARTH GROUND R...

Страница 32: ...ries inside the device s electronic system and any other removable component if it is proved that their condition is due to a manufacturing defect rather than the effects of wear electric and electron...