3. Technical Specification
-
Size: DN3
,
6, 8, 10
,
15
,
20mm
(
Can be customized
) -
Velocity range: 0.01m/s – 10 m/s
-
Accuracy: ±0.5% of RS (Velocity>0.6m/s) or ±3mm/s(Velocity≤0.6m/s)
-
Repeatability: 1/3 of accuracy
-
Temperature: PT1000, 0.1
℃
resolution
-
Media Conductivity: 20 ms/cm
-
Measuring Direction: Bi-directional measurement
-
Max Working Pressure: 1.0MPa
-
Max Working Temperature: 60
℃
for PE liner, 90
℃
for PEEK or Ceramic liner
-
Liner: PE, PEEK, Ceramic
-
Electrodes: SS316L or HC
-
Enclosure: Aluminum, IP65 for Blind version
-
Connection: G1/2 or NPT 1/2
-
Power supply: 24VDC, ≤100mA
-
LCD display: flow rate and total flow
-
Analog output: 4 – 20mA
-
Pulse output: 0 – 5K Hz
-
Relay Output: optional, 1 Relay 2A/30VDC
-
RS485 MODBUS: Optional for Display version, Standard for Blind version
4. Installation
Mini magmeter can be installed horizontally or vertically. It is recommended that the meter