7. Safety and precautions

Before installation and initial operation of the frequency converter, please read through the product handbook carefully and 

observe all warnings and safety precautions. Make sure that the product manual is easily reachable in the area of the frequency 

converter.

Definition of tips:

Warning!

 Failure to comply with this information could cause death, severe bodily injury or significant physical damage.

Caution!

 Failure to comply with this information could cause minor bodily injury or physical damage.

General:

 During operation it must be ensured that the mains voltage is constantly on.

Warning!

  This frequency converter creates dangerous electrical voltage and controls dangerous rotating parts. Failure to comply with the 

information in this manual could cause death, severe bodily injury or significant physical damage.

  The installation, initial operation and maintenance of this drive may only be performed by expert staff that are well versed in 

the functionality and equipment as well as the machine. 

  The device contains intermediate circuit capacitors that also carry out switchover of dangerously high voltages on the grid side. 

After switching off the voltage, wait at least 15 minutes before opening the device and working on it. Please be sure that no live 

parts are touched.

  The ground fault safety serves only as protection for the frequency converter and not as personal protection. In accordance 

with VDE 0160 (German abbreviation for the Association for Electrical, Electronic &Information Technologies), the three-

phase frequency converter must not be operated on a leakage current circuit breaker, because a possible direct current 

component will reduce the sensitivity of the leakage current circuit breaker in the event of a fault. 

  The provisions of VDE 0160 should be observed as protective measures.

  Ground the frequency converter to the connection provided for it.

  To avoid injury and damage, do not touch any parts within the housing – not with hands or any kind of object – when mains 

voltage is present or the intermediate circuit capacitor is not loaded. Do not work on wiring or test signals when mains 

voltage is present.

  Pay special attention when the automatic restart is activated. To avoid injury from possible uncontrolled restart of the fre-

quency converter after a power outage, install a switch element on the grid side that de-energises in a power outage and can 

only be turned on after return of voltage by manual confirmation (e.g., contactor, etc.).

  Ensure that the input voltage corresponds with the voltage listed on the label. Environmental influences such as high tempera-

ture and high humidity are to be avoided as well as dust, dirt and aggressive gases. 

  The install location should be a well-ventilated location away from direct sunlight. Install the device on a non-flammable, 

vertical wall that does not transmit vibrations. Do not connect mains voltage to the output terminals U/T1, V/T2, W/T3.

  Please contact the motor or machine manufacturer if standard motors with a frequency of  > 60 Hz will be operated. 

  All frequency converters are tested for dielectric strength and insulation resistance measurements. Insulation resistance 

measurements, for example, in the course of inspection, must not be conducted between the power terminals and earth. Do 

not carry out insulation resistance measurements on the control terminals. 

  During operation it must be ensured that the mains voltage is constantly on. Control commands and operating signals (such 

as start/stop) must only be implemented via the control terminals or the control panel and not by switching the mains supply 

or a motor contactor. 

  Do not install capacitors or overvoltage arrestors in the motor lead.

Caution!

  In order to guarantee that your Klingenburg frequency converter operates securely and reliably, all respective safety regula-

tions, such as accident prevention regulations, VDE regulations, etc,. must be observed. 

  As these regulations could contain different details within the German speaking areas, the user must observe the require-

ments that are valid for their area. 

  Klingenburg GmbH cannot exonerate the user from the obligation to follow the most current safety regulations. The technical 

data and descriptions in these operating instructions are compiled according to the best of our knowledge and belief. Prod-

uct improvements are constantly performed. For this reason, Klingenburg GmbH reserves the right to make such changes 

without prior notice.

  Despite the careful creation of these instructions, Klingenburg GmbH cannot be held liable for errors or damage which arise 

from use of this manual.

Содержание KR4

Страница 1: ...N E R G Y R E C O V 1 Function of the controller 2 Terminal connections 3 Technical data 4 Initial operation 5 Manual mode external mode 6 Trouble shooting and fault messages 7 Safety and precautions...

Страница 2: ...short circuit proof outlet EN 55011 tested EN 61000 3 tested EN 61000 4 2 tested EN 61000 4 3 burst tested EN 61000 4 4 surge tested EN 61800 3 tested every individual module is tested detailed fault...

Страница 3: ...ly voltage of 24 Volt on the contacts 5 7 9 and optional 14 3 Technical data Controller typ KR4 KR7 Output 0 4 kW 0 75 kW Fuse internal 6 3 A delay 5 x 20 mm 10 A delay 5 x 20 mm Mains voltage 220 240...

Страница 4: ...z C o n t r b l o c k e d P l e a s e w a i t Navigating through the menu items You can choose between English and German Other menu languages are available upon request The change is made by activat...

Страница 5: ...g cycle ensures that the rotor moves regularly in a half rotation if no request comes from the controller signal or keypad for longer than 20 minutes 0 5 S t a r t p o i n t F r e q u e n c y 8 0 H z...

Страница 6: ...t f r e q 4 0 H z N o m f r e q 4 0 H z If the following image should appear instead Check the following table of errors Search method for KR4 KR7 base controller no display is visible test the fuse c...

Страница 7: ...r overloaded 09 Mains under voltage 14 Earth fault 15 Mains overvoltage 21 Overtemperature in the power amplifier environmental temperature too high controller overloaded 99 Software error The control...

Страница 8: ...restart is activated To avoid injury from possible uncontrolled restart of the fre quency converter after a power outage install a switch element on the grid side that de energises in a power outage a...

Страница 9: ...Klingenburg GmbH Boystra e 115 45968 Gladbeck Germany Tel 49 20 43 96 36 0 Fax 49 20 43 7 23 62 E mail klingenburg klingenburg de www klingenburg de E N E R G Y R E C O V E R Y DNKR4 7 Status 01 14...

Отзывы: