User’s Manual
K&F ‘SW’ Series Subwoofer Systems
KLING & FREITAG GMBH ©1998 - 2006
Version 4.0, 23.03.2006
Page 25 of 47
9.2.1
‘XO OFF’ or Subwoofers without optional Crossover
Operations with Controller C2 in 2-way active mode
2
1
3
2
1
3
CH 2
CH 1
2
1
3
2
1
3
AMP BASS
CH 2
CH 1
+
-
-
+
CH 2
CH 1
AMP MID/HIGH
CH 2
CH 1
+
-
-
+
UNIT
INPUT
INPUT
CHANNEL 2 LINK
CHANNEL 2 IN
CHANNEL 1 IN
CHANNEL 1 LINK
CH2 SUB AMP
(OPTIONAL)
REMOTE
REMOTE CONTROL
240V / 50Hz
CE
FUSE: 100mA / SLOW BLOW
MADE IN GERMANY
KLING &
FREITAG
SER No.
INPUT
SY
ST
E
M
CO
N
TR
O
LL
ER
-LF+
CH1 TOP AMP
CH1 SUB AMP
CH2 TOP AMP
CH1 INPUT
GND
LIFT
CH2 INPUT
-HF+
C2
-LF+
-LF+
-HF+
-LF+
AMP RETURN CH2
AMP RETURN CH1
ALL SPEAKONS
1+/1-
CH1 TOP OUT
KLING &
FREITAG
SOUND SYSTEMS
CH1 SUB OUT
CH2 TOP OUT
CH2 SUB OUT
FULLRANGE
MODE
TOP
HF
BOOST LOW CUT
GAIN
SUB
INPUT GAIN
C2
SYSTEM
CONTROLLER
C
H
2
TO
P
S
IG
N
A
L
C
H
2
TO
P
L
IM
IT
P
O
W
ER
C
H
1
TO
P
S
IG
N
A
L
C
H
1
TO
P
L
IM
IT
SUB
MONO
C
H
1
SU
B
SI
G
N
A
L
C
H
1
SU
B
LI
M
IT
C
H
2
SU
B
SI
G
N
A
L
C
H
2
SU
B
LI
M
IT
LINK, e.g. to next controller
For using Subwoofers
with XO, set switch on
the back to 'XO OFF'
The switch XO on the connecting terminal of the subwoofer must be at XO ‘OFF’ for
this mode of operation:
Switch on the subwoofers’ connecting terminal
The countersunk switch ‘Full-Range Mode’ on the C2 Controller should not be pressed
and the LED assigned to it should not light up.
If you are using the mid-high systems in a cluster (speakers in close proximity), press the
‘Top Low Cut’ switch on the C2 Controller.
Advantages of the active mod:
−
Possibility to separately adjust the level of the subwoofer.
−
The mid-high systems do not receive any low-frequency signals and are not as
strained.
−
Higher achievable total sound power level.
−
While taking the various mid-high systems, the frequency response of the system
can be optimised application-specifically.
−
The C2 Controller optimises the operating safety through special limiters.