9.

 

Operating the Speakers 

 

Switch off all equipment and turn down all level controls. 

 

Wire the E 90 MK II systems according to the wiring diagrams as shown be-
fore. 

 

Upon completing the wiring, ensure that the connected speaker channels are 
working in phase. To do so, use i.e. a phase checker. A phase error can also 
be recognized when the connected channels are used simultaneously. During 
simultaneous use the bass frequencies become notably quieter or the mid-
frequencies such as voices cannot be located. 

 

Now switch on the peripheral equipment first (mixing console, effects etc.), 
followed by the power amplifiers. Always use the before mentioned switching 
order. Otherwise switching noises may damage the system. 

 

If there is interference, turn off all appliances in the reverse order and check all 
cable connections (see chapter 7.2 ). 

 

Now put a low level signal into the system and check for the correct function 
of the system. In doing so, all amplifier input controls need to be turned off 
again. Now turn on the control for the left E 90 MK II system and check that 
the correct signal is coming out of the E 90 MK II system. 

 

Your system should now be ready for operation. 

 

Turning down the input level controls may not always prevent distortions in 
the input section of the power amplifier, especially if this section has a rela-
tively low headroom. A clipping signal may not be displayed by the clipping 
indicator then. To prevent signal interruptions or damages to the speakers, 
turn the level controls of the power amplifier to the maximum position, if pos-
sible. The output level of the mixing console or the controller should be set to 
a level that doesn't overload the power amplifiers. 

 

When turning off the system, the input controls for the power amplifiers 
should be turned down first followed by the power switches of the amplifiers. 
After that, the other appliances can be turned off. 

 

The crossovers of the E 90 MK II systems are equipped with protection circuits 
for the 1’’ and 5’’ drivers. These circuits cut off the signal current when highly 
overloaded. If the high speaker turns off, reduce the volume. After a few sec-
onds, it will turn back on automatically. 

 

Important 

Содержание E 90 MK II

Страница 1: ...106 F weicht in Form und Aussehen von dieser Abbildung ab KLING FREITAG GmbH Junkersstrasse 14 D 30179 Hannover PHONE 49 0 511 96 99 70 FAX 49 0 511 67 37 94 www kling freitag de Important Information...

Страница 2: ...User s Manual E 90 MK II KLING FREITAG GMBH 1995 2006 Version 4 0 02 11 2006 Page 2 of 22...

Страница 3: ...structions may cause minor injuries or property damage Important This symbol gives instructions for the proper use of the described prod ucts Not following these instructions may cause malfunctions or...

Страница 4: ...oper Arrangement of the Loudspeakers 10 7 Wiring 11 7 1 Connecting the Speakon Connector to the Terminal 11 7 2 Avoiding Ground Loops 12 7 2 1 What is a Ground Loop 12 7 2 2 Avoiding Ground Loops 12 8...

Страница 5: ...and mounting Instructions for loudspeakers and accessories Speakers and rigging equipment must be visually examined at regular intervals If there are signs of wear they must be replaced immediately Fu...

Страница 6: ...unlight where the speakers are exposed to high moisture or rain where the speakers are exposed to strong vibrations and dust Damage caused by the speakers magnetic fields Speakers are permanently surr...

Страница 7: ...oidal enclosure 15 mm birch plywood with highly resistant structured paint in black RAL 9005 grey RAL 7016 or white RAL 9010 3 x M6 thread inserts for mounting accessories highly permeable ball proof...

Страница 8: ...utdoor must still be protected from direct effects of the weather They should be installed for example under a roof so that they also have sufficient protection from driving rain from the side and dir...

Страница 9: ...The 100 V transformer for the E 90 MK II has 3 taps These enable the speaker to be operated at 50 VA 100 VA or 150 VA Which tap is connected to which pin can be seen below 5 Instructions for Suspendin...

Страница 10: ...sult It is not possible to make generalities about the alignment of specific systems because the room has a substantial influence on the signal and the audible result As a rule the mid and high transd...

Страница 11: ...ify the pin configu ration on the power amplifiers or on the connectors leading to them Upon completing the wiring ensure that the connected speaker channels are work ing in phase To do so use i e a p...

Страница 12: ...a ground loop before the power amplifiers controllers e g mixing console effects or equalizers the system or parts of the system are connected to an unclean power sup ply meaning one which is also run...

Страница 13: ...integrated or preceding subsonic filter approx 30 Hz min 12 dB octave integrated clipping limiter maximum rated power 300W 8 equivalent 600W 4 8 1 E 90 MK II Systems in Full Range Mode This mode of op...

Страница 14: ...E 90 MK II systems with K F subwoofers 2 E 90 MK II systems 1 2 x SW 112 XO 2 4 E 90 MK II systems 1 x SW 115D XO 2 4 E 90 MK II systems 1 x SW 115E XO 2 4 E 90 MK II systems 1 x SW 118E XO INPUT CH 2...

Страница 15: ...plifier input controls need to be turned off again Now turn on the control for the left E 90 MK II system and check that the correct signal is coming out of the E 90 MK II system Your system should no...

Страница 16: ...t proof and ex tremely resistant we recommend using protective coverings or cases to help avoid damaging the paint during i e continuous mobile use If paint damage occurs despite these precautions it...

Страница 17: ...tached horn Crossover 3 5 kHz 18 dB octave self resetting protection circuit for 5 and 1 drivers Impedance 8 Zmin 7 2 Connectors 2 x Speakon NL4MP 1 1 Enclosure Trapezoidal enclosure 15 mm frame reinf...

Страница 18: ...1000 10000 20000 65 75 85 95 105 Frequency response Frequency Hz SPL dB 3 16 10 31 6 100 Impedance Impedance Ohm Beamwidth 20 100 1000 10000 20000 0 60 120 180 240 300 360 Horizontal Vertical 6dB Beam...

Страница 19: ...22 Horizontal coverage 125 250 500 1k 2k 4k 8k 16K 180 150 120 90 60 30 0 30 60 90 120 150 180 f Hz Attenuation dB 3 6 6 9 9 12 12 15 15 18 18 3 l Vertical coverage 125 250 500 1k 2k 4k 8k 16K 180 15...

Страница 20: ...90 MK II KLING FREITAG GMBH 1995 2006 Version 4 0 02 11 2006 Page 20 of 22 14 Dimensions 9 internal threads M6 170 mm 6 693 175 mm 6 890 200 mm 7 875 670 mm 26 378 112 5 mm 4 431 125 mm 4 921 25 mm 0...

Страница 21: ...6 Version 4 0 02 11 2006 Page 21 of 22 15 Accessories Adjustable speaker mount E 90 U mount E 90 Stand adapter TV spigot adapter Pipe Clamp TV spigot Eyebolt M6 x 15 Further information is available i...

Страница 22: ...domestic waste is prohibited and that the product has been put into circulation at the 03 24 2006 earliest The Kling Freitag GmbH has been legally registered as a manufacturer with the registration o...

Отзывы: