Operation and installation manual 2015.12.07
3
Tab. 2. Technical parameters of the KLIMOSZ DUOPELET NG.
Parameter
SI
KLIMOSZ
DUOPELET
55
KLIMOSZ
DUOPELET
75
KLIMOSZ
DUOPELET
100
KLIMOSZ
DUOPELET
150
AUTOMATIC MODE
Nominal power – pellets (max / nominal)
kW
50 / 47
75 / 62
97 / 90
140 / 120
Efficiency - pellets
%
91
91,5
90,0
90,0
Fuel consumption at nominal power
- pelety 18MJ/kg
kg/h
11,0
16,8
21,8
29,8
Approximate combustion time at nominal power –
pellets
h
56,8
37,5
28,9
21,1
Range of power – pellets
kW
15 ÷ 50
22,5 ÷ 75
29,1 ÷ 97
42 ÷ 140
Flow of fumes - pellets – nominal power
g/s
17
19
21
22
Fumes temperature
°C
100 ÷ 220
100 ÷ 220
100 ÷ 240
100 ÷ 240
Boiler class
-
4
5
3
5
Approximate combustion time – Wood
h
2
2
2
2
Mass
kg
820
960
1415
1575
Heating area of the boiler
m
2
5,8
8,1
11,1
15,2
Water volume
dm
3
148
195
260
360
Diameter of fumes outlet
mm
200
200
200
200
Chimney draught
Pa
20 ÷ 30
20 ÷ 30
20 ÷ 35
25 ÷ 35
Capacity of the fuel tank
dm
3
700
700
700
700
Water maximal working pressure
bar
1,8
2,0
2,0
2,0
Water minimal working pressure
bar
-
-
-
-
Water maximal trial pressure
bar
2,7
3,0
3,0
3,0
Recommended working temperature for heating
water
°C
65 ÷ 80
Maximal working temperature for heating water
°C
90
Minimal temperature of water returning to the boiler
°C
50
Maximal permitted level of heating material
m
18
20
20
20
Noise level
bar
1,8
2,0
2,0
2,0
Poziom hałasu
dB
< 65 (A)
Connections of the boiler - heating and returning
water
2”
2 1/2”
Resistance of water flow through the boiler
mbar
1,4 / 0,4
Voltage
230V / 50 Hz
Electric energy consumption (fan / motor)
W
50 / 45
Electric energy consumption (shot light-option)
W
700
Electric insulation
IP 40