Klimawent ERGO-KOS-AL Скачать руководство пользователя страница 9

 

 9 

 

 

 

 

30.01.2019

                                       

extraction rail

  ERGO-KOS-AL  

 

 

Tab No. 2  

–  WPA-E-N  –  Technical Data

:

 

Type of the fan 

 

 

 

 

Synchronous 

rotations 

 

 

[r.p.m.] 

Supply 

voltage 

 

 

[V] 

Motor 

rate 

 

 

[kW] 

Ingress 

protection 

 

 

IP 

Acoustic 

pressure level 

[dB(A)]   

from distance 

Maximum 

volume flow 

 

 

[m

3

/h] 

Maximum 

vacuum

 

 

 

[Pa] 

Weight 

 

 

 

[kg] 

1m  

5m 

WPA-3-E-1-N 

3000 

230 

0,25 

54 

78/70*  64/56* 

1160 

940 

12 

WPA-3-E-3-N 

3 x 400 

WPA-5-E-1-N 

3000 

230 

0,37 

54 

76/67*  62/53* 

1900 

1250 

16,5 

WPA-5-E-3-N 

3000 

3 x 400 

0,37 

54 

76/67*  62/53* 

1900 

1250 

WPA-6-E-1-N 

3000 

230 

0,75 

54 

83/75*  69/61* 

2500 

1700 

21 

WPA-6-E-3-N 

3000 

3 x 400 

0,75 

54 

83/75*  69/61* 

2500 

1700 

WPA-7-E-1-N 

3000 

230 

1,1 

54 

86/74*  72/60* 

3100 

1800 

23 

WPA-7-E-3-N 

3000 

3 x 400 

1,1 

54 

86/74*  72/60* 

3100 

1800 

WPA-8-E-3-N 

3000 

3 x 400 

1,5 

54 

88/78*  74/64* 

3900 

2050 

29 

WPA-9-E-3-N 

3000 

3 x 400 

2,2 

54 

91/82*  77/68* 

4500 

2400 

36 

WPA-10-E-3-N 

3000 

3 x 400 

3,0 

54 

91/81*  77/67* 

6200 

2450 

50 

WPA-11-E-3-N 

3000 

3 x 400 

5,5 

54 

97/88*  83/74* 

8050 

2950 

64 

WPA-13-E-3-N 

3000 

3 x 400 

7,5 

54 

99/90*  85/76* 

10800 

3300 

85 

a/ 

For applications with a fan  located on the roof we suggest using the fan  

WPA-D-N

  series  

of fans of KLI-MAWENT S.A. production. 

 
 

 

Fig. No.8  

–  WPA-D-N  –  Flow charts

 

 

Содержание ERGO-KOS-AL

Страница 1: ...cation 2 3 Reservations of Producer 2 4 Technical Data 2 5 Structure and Function 4 6 Assembly and Start up 4 7 Operational Use 10 8 Troubleshooting Guide 10 9 Maintenance 11 10 Occupational Health an...

Страница 2: ...pts general principles for design Risk assessment and risk reduction 2 Application ERGO KOS AL is designed for extraction of welding fumes at mobile workplaces for linear wel ding of elements of lengt...

Страница 3: ...n Sort of the connection Type Part No Diameter Remarks for axial connection KPC 804K20 160 To connect the suction duct to the extraction installation Duct hanger Sort of the hanger Type Part No Remark...

Страница 4: ...elding the operator displaces the ERGO extraction arm with the trolley along the suc tion duct The suction hood ought to be adjusted at a distance at least ca 30 cm from the wel ding point Fig No 1 ER...

Страница 5: ...tion duct Slide the OP ERGO L trolley into the KOS AL suction duct in such a way that the trolley rollers are displacing on the side guide rails of the duct profile two straps of the rubber apron shou...

Страница 6: ...uction side of the fan connecting the self tightening duct with the fan c roof fan Extraction system with a fan for indoor installing a assembly of the KOS AL self tightening suction duct and trolley...

Страница 7: ...7 30 01 2019 extraction rail ERGO KOS AL Fig No 5 Fig No 6...

Страница 8: ...type T before the fan inlet the silencer length ought to be not less than 500 mm to connect the inlet and outlet of the fan with the installations by means with a flexible joint Flexible joints do no...

Страница 9: ...A 6 E 1 N 3000 230 0 75 54 83 75 69 61 2500 1700 21 WPA 6 E 3 N 3000 3 x 400 0 75 54 83 75 69 61 2500 1700 WPA 7 E 1 N 3000 230 1 1 54 86 74 72 60 3100 1800 23 WPA 7 E 3 N 3000 3 x 400 1 1 54 86 74 72...

Страница 10: ...fficiently eliminates the fume and dustiness not causing excessive draft During the operational use the position of the extraction arm and of the shut off lever can be changed several times adapting t...

Страница 11: ...evere hazard to personnel people in the vicinity Start up and maintenance are exclusively possible after getting acquainted with the contents of the present Use and Maintenance Manual For the safety r...

Страница 12: ...ion and with the present Use and Maintenance Manual mechanical damages and malfunctions caused by User changes modifications introduced by User on one s own malfunction resulting from the normal opera...

Страница 13: ...13 30 01 2019 extraction rail ERGO KOS AL...

Страница 14: ...030 335 160 Fig No 10 ERGO LUX L 2 ERGO LUX L 3 extraction arms Type L m A mm B mm C mm D mm E mm nxF mm G mm ERGO FLEX LUX 2 2 0 930 435 355 160 194 6x 6 5 295 ERGO FLEX LUX 3 3 0 1510 846 355 160 19...

Страница 15: ...Parliament and of the Council of May 17th 2006 on machinery amen ding the 95 16 EC recast Journal of Laws EC L157 of 09 06 2006 page 24 The appliance meets following harmonized standard EN ISO 12100 2...

Страница 16: ...16 extraction rail ERGO KOS AL 30 01 2019 NOTES...

Отзывы: