Klimawent ERGO-KOS-AL Скачать руководство пользователя страница 5

 

 5 

 

 

 

 

30.01.2019

                                       

extraction rail

  ERGO-KOS-AL  

 

 

 

Fig. No.2  

–  Installing example  of the suction duct  –  through an intermediate beam to 

 

the roof truss in a high ceiling process hall 

 
Because of the high requirements for the installing of the system 

– these works should be exe-

cuted exclusively  by an installing team of the manufacturer or under supervision of an authori- 
zed person.   There are special guidelines in the Assembly Instructions of the KOS-AL suction 
duct and in for the extraction arms. 
 

Installing the trolley on the suction duct

:

 

Slide the OP-ERGO-L trolley into the KOS-AL suction duct 

– in such a way that: 

– 

the trolley rollers are displacing on the side guide-rails of the duct profile, 

– 

two straps of the rubber apron  should hold the suction fitting of the trolley from both sides. 

 

Installing of the ERGO extraction arms: 

Extraction trolley is equipped with a flange  that is identical with the one at the mounting swivel  
of the ERGO LUX and ERGO-FLEX LUX extraction arm.  The swivel ought to be fixed through  
M6 bolts (6 pieces) to the trolley flange. 
 

NOTE

:   

 
The extraction arms themselves ought to 
be assembled according to their manual / 
assembly instruction for extraction arms. 
Extraction arms  are delivered  in a partly 
assembled state. 

 

 
 
 
 

                                     Fig. No 3 

 
 

 

Содержание ERGO-KOS-AL

Страница 1: ...cation 2 3 Reservations of Producer 2 4 Technical Data 2 5 Structure and Function 4 6 Assembly and Start up 4 7 Operational Use 10 8 Troubleshooting Guide 10 9 Maintenance 11 10 Occupational Health an...

Страница 2: ...pts general principles for design Risk assessment and risk reduction 2 Application ERGO KOS AL is designed for extraction of welding fumes at mobile workplaces for linear wel ding of elements of lengt...

Страница 3: ...n Sort of the connection Type Part No Diameter Remarks for axial connection KPC 804K20 160 To connect the suction duct to the extraction installation Duct hanger Sort of the hanger Type Part No Remark...

Страница 4: ...elding the operator displaces the ERGO extraction arm with the trolley along the suc tion duct The suction hood ought to be adjusted at a distance at least ca 30 cm from the wel ding point Fig No 1 ER...

Страница 5: ...tion duct Slide the OP ERGO L trolley into the KOS AL suction duct in such a way that the trolley rollers are displacing on the side guide rails of the duct profile two straps of the rubber apron shou...

Страница 6: ...uction side of the fan connecting the self tightening duct with the fan c roof fan Extraction system with a fan for indoor installing a assembly of the KOS AL self tightening suction duct and trolley...

Страница 7: ...7 30 01 2019 extraction rail ERGO KOS AL Fig No 5 Fig No 6...

Страница 8: ...type T before the fan inlet the silencer length ought to be not less than 500 mm to connect the inlet and outlet of the fan with the installations by means with a flexible joint Flexible joints do no...

Страница 9: ...A 6 E 1 N 3000 230 0 75 54 83 75 69 61 2500 1700 21 WPA 6 E 3 N 3000 3 x 400 0 75 54 83 75 69 61 2500 1700 WPA 7 E 1 N 3000 230 1 1 54 86 74 72 60 3100 1800 23 WPA 7 E 3 N 3000 3 x 400 1 1 54 86 74 72...

Страница 10: ...fficiently eliminates the fume and dustiness not causing excessive draft During the operational use the position of the extraction arm and of the shut off lever can be changed several times adapting t...

Страница 11: ...evere hazard to personnel people in the vicinity Start up and maintenance are exclusively possible after getting acquainted with the contents of the present Use and Maintenance Manual For the safety r...

Страница 12: ...ion and with the present Use and Maintenance Manual mechanical damages and malfunctions caused by User changes modifications introduced by User on one s own malfunction resulting from the normal opera...

Страница 13: ...13 30 01 2019 extraction rail ERGO KOS AL...

Страница 14: ...030 335 160 Fig No 10 ERGO LUX L 2 ERGO LUX L 3 extraction arms Type L m A mm B mm C mm D mm E mm nxF mm G mm ERGO FLEX LUX 2 2 0 930 435 355 160 194 6x 6 5 295 ERGO FLEX LUX 3 3 0 1510 846 355 160 19...

Страница 15: ...Parliament and of the Council of May 17th 2006 on machinery amen ding the 95 16 EC recast Journal of Laws EC L157 of 09 06 2006 page 24 The appliance meets following harmonized standard EN ISO 12100 2...

Страница 16: ...16 extraction rail ERGO KOS AL 30 01 2019 NOTES...

Отзывы: