4
Filtering unit
BIG-2000-N 26.06.2019
2.
Application
BIG-2000-N filtering unit is appropriate for cleaning
the
air contaminated with dust-
and
gaseous
impurities, arising during various manufacturing processes.
It is perfect in removal of dry dust and fumes emitted during welding, gaseous metal cutting and
during other processes, in chemical industry, food processing
, pharmaceutics,
plastic
processing
.
The appliance is not appropriate for capturing humid dust and aggressive compounds and sub-
stances causing explosion risk. The maximum temperature of the conveyed air is +60ºC.
The filtering unit is equipped with automatic cleaning system for the cartridge filter, therefore the
dust particles
(accumulated on the filter’s outer surface) are
periodically struck off by the impulses
of compressed air.
3.
Reservations of Producer
A
.
Manufacturer accepts no liability for any consequences following from the operational use
that is in contradiction to the purpose of application.
B
.
Installing of any additional elements
not belonging to the
normal device structure
(or acces-
sory set) is not acceptable.
C
.
Any structural changes or modification
of the
filtering unit, carried
out by
User on
one’s
own
are not permitted.
D
.
Protect the housing from mechanical damage.
E
.
The appliance is not appropriate
for conveying the air that is contaminated with a mix-
ture of flammable substances, in the form of gas, vapour, mist or dust, which would
create explosive atmosphere with the air.
F
.
Do not use the filtering unit
for cleaning the air polluted with aggressive substances which
could exert destructive effect on the device.
G
.
Manufacturer is not responsible for wounds / body
laceration
caused in the course of impro-
per operational use.
H
.
In the course of operational use, pay
attention
that any
sources
of
ignition
i.e. glowing
cigarette butts would not get into the filtration chamber.
4.
Technical Data
Table No.1
Type of the
device
Maxi-
mum
volume
flow
Maxi-
mum
vacuum
Supply
voltage
Current Motor
rate
Acoustic
pressure
level
from
distance
Consump-
tion of
compres-
sed air
Weight
1m
5m
[m³/h]
[Pa]
[V]
[A]
[kW]
[dB(A)]
[kg]
BIG-2000-N
2500
2000
3x400 2,8
1,5
74
60
0,7
260
CAUTION
:
1
. Quantity of connections for extraction arms – 2
2
. Volume flow has been measured at the clean filter
3
.
Complete assortment of
extraction arms is
represented on separate catalogue
cards
Содержание BIG-2000-N
Страница 1: ...1 26 06 2019 Filtering unit BIG 2000 N Use and Maintenance Manual Filtering unit BIG 2000 N...
Страница 8: ...8 Filtering unit BIG 2000 N 26 06 2019 Fig No 2 Connection diagram filtering unit BIG 2000 N...
Страница 15: ...15 26 06 2019 Filtering unit BIG 2000 N Fig No 6 Compressed air tank...
Страница 18: ...18 Filtering unit BIG 2000 N 26 06 2019 NOTES...
Страница 19: ...19 26 06 2019 Filtering unit BIG 2000 N NOTES...