START-UP OF THE APPLIANCE
:
1
.
Open the compressed air valve.
2
.
Insert the plug into the power supply socket.
3
.
Switch on the motor switch
Q1M
.
4
. Switch on the power supply by setting the
S1
into position “
ON
” ; this will be indicated
by the white lamp
S1.H1
.
5
.
The system of the initial- and final regeneration is in operation – the relays
K2T
,
K3T
are controlling the impulses of the electromagnetic valve. Within the time of 3 minutes,
every 30 seconds
the valve opens and the impulse of compressed air cleans the filter.
At any moment (during the filter regeneration) the device can be switched on.