background image

PARTS NAMES 

INDOOR UNIT

OUTDOOR UNIT

DISPLAY PANEL

AUTO

AUTO

TIMER

TIMER

PRE.-DEF.

Air outlet

Air-outlet

Air inlet

OPERATION

OPERATION

1

3

4

5

6

7

9

10

11

12

8

2

Air-inlet

OUTDOOR UNIT

NOTE:

DISPLAY PANEL

AUTO indicator:

INDOOR UNIT

Front panel

Front panel frame 

Air filter

Vertical airflow louver

Horizontal airflow grille

Display panel

Infrared signal receiver

Manual control button

Remote controller

Drain hose, refrigerant connecting pipe

Electric wiring

Stop valve

OPERATION indicator:

This indicator flashes  once per second after 
power is on and illuminates when the air 
conditioner is in operation.

TIMER indicator:

This indicator illuminates when TIMER is set ON.

PRE.-DEF.indicator  (cooling/heating only):

The  air  conditioner  starts defrosting 
automatically  if outdoor unit frosts in heating
operation. At this time, PRE.-DEF. Indicator
illuminates.

When you set the air conditioner to AUTO mode,
the indicator starts flashing.

NOTE:

            All the pictures in this manual are for explanation
            purposes only. The actual shape of your air 
            conditioner may be slightly different, but the
            operation instructions are the same.

The OPERATION indicator  flashes rapidly (five
 times per second.) when  protection feature is
 activated.

1

3

4

5

6

7

8

9

10

11

12

2

Cooling Only

Cooling/Heating

3

FAN ONLY

FAN ONLY indicator:

When you set the air conditioner to FAN ONLY
mode, this indicator illuminates.

Содержание KSWM

Страница 1: ...lease read the operating instructions and safety precautions carefully and thoroughly before installing and operating your room air conditioner OWNER S MANUAL Split Type Room Air Conditioner KSWM unit...

Страница 2: ...ms in the chart of troubleshooting tips If you review the chart of Troubleshooting Tips first you may not need to call for service Contact an authorised service technician for repair or maintenance of...

Страница 3: ...earthing may cause electric shock It may cause fire and electric shock It may cause fire It may cause explosion fire and burns It may cause electric shock or fire due to heat generation It may cause...

Страница 4: ...er to preserve precision devices food pets plants and art objects It may cause deterioration of quality etc It may cause failure of product or fire Do not use for special purposes Turn off the main po...

Страница 5: ...er is in operation TIMER indicator This indicator illuminates when TIMER is set ON PRE DEF indicator cooling heating only The air conditioner starts defrosting automatically if outdoor unit frosts in...

Страница 6: ...rature 1 If air conditioner is used outside of the above conditions certain safety protection features may come into operation and cause the unit to function abnormally 2 Room relative humidity less t...

Страница 7: ...he AIR DIRECTION button on the remote controller to move the louver to the desired direction Adjust the vertical air flow direction to the desired direction In subsequent operations the vertical air f...

Страница 8: ...ting cooling heating models only or fan only operation depending on what temperature you have selected and the room temperature The air conditioner will control room temperature automatically round th...

Страница 9: ...NING MAINTENANCE Filter Handle Thinner 7 Use a dry cloth to wipe the indoor unit and remote controller A cloth dampened with cold water may be used on the indoor unit if it is very dirty The front pan...

Страница 10: ...he filter Injuries can occur when handling sharp metal edges Do not use water to clean inside the air conditioner Exposure to water can destroy the insulation leading to possible electric shock When c...

Страница 11: ...relative humidity A white mist may generate due to moisture generated from defrosting process when the air conditioner restarts in HEAT mode operation after defrosting 3 Low noise of the air conditio...

Страница 12: ...emperature If a comfortable temperature can t be achieved by the air conditioner we suggest you use a supplementary heating device 9 Auto restart function Power failure during operation will stop the...

Страница 13: ...wn Battery in Remote controller may have been exhausted The time you have set with timer is incorrect Wait for power to be restored Check that plug is securely in wall receptacle Replace the fuse Repl...