![Klimaire KSIF009-H115-I Скачать руководство пользователя страница 18](http://html1.mh-extra.com/html/klimaire/ksif009-h115-i/ksif009-h115-i_service-manual_1977790018.webp)
16
8. Electronic function
8.1 Abbreviation
T1: Indoor room temperature
T2: Coil temperature of evaporator
T3: Coil temperature of condenser
T4: Outdoor ambient temperature
T5: Compressor discharge temperature
8.2 Display function
8.2.1 Icon explanation on indoor display board.
“fresh” when fresh feature is activated(if
applicable).
“defrost” when deforsting is activated.
“run” when the unit is on.
“timer” when TIMER is set.
Digital display(for some units):
Displays the temperature settings when the air
conditioner is operational.
Displays the room temperature in Fan and
Drying mode.
Displays the self-diagnostic codes.
Dispalys ‘
’ for three seconds when Timer
ON, Fresh, Swing, Turbo or Silence feature is
activated.
Dispalys ‘
’ for three seconds when Timer
OFF,Fresh, Swing, Turbo or Silence feature is
cancelled.
Dispalys ‘
’ under deforsting operation.
Dispalys ‘
’ when anti-cold air feature is
activated under heating mode.
Dispalys ‘
’ during self clean operation (if
applicable).
Dispalys ‘
’ when freeze protection is
turned on (if applicable).
NOTE: