ENGLISH

OPERATING INSTRUCTIONS

AC CURRENT (LESS THAN 400A)

AC Current is measured by pressing the clamp trigger 

10

 to open 

the clamp and placing it around a current-carrying wire. When 
measuring, care should be taken to ensure that the clamp is 
completely closed with trigger 

10

 fully released, and that the wire 

passes perpendicularly through the center of the clamp in line with 
the arrow markings 

11

.  

To measure current:

1.  Rotate the Function Selector switch 

2

 to the 200/400 A setting. 

2.  Place clamp around wire. The current measurement will be shown 

in the display.

NOTE:

 If the measurement is less than 20A, rotate the Function 

Selector switch 

2

 to the 2/20 A setting for improved resolution.

 

Disconnect test leads when measuring with the clamp.

WIRE

CL210-1390114ART.indd   8

10/1/2015   3:42:26 PM

Содержание CL210

Страница 1: ...Dwg Ref 1290186 Color Reference N A INSTRUCTION MANUAL ENGLISH CL210 FRAN AIS pg 29 ESPA OL pg 15 400A AC Auto Ranging Digital Clamp Meter AUTO RANGING DATA HOLD RANGE HOLD TEMPERATURE AUDIBLE CONTIN...

Страница 2: ...n ambient working temp is outside of Accuracy Temp range Dimensions 8 66 x 3 03 x 1 61 220 x 77 x 41 mm Weight 9 88 oz 280 g including batteries Calibration Accurate for one year Standards Conforms to...

Страница 3: ...gits 20 00A 10mA 2 0 10 digits 200 0A 100mA 400A 1A Frequency Range 50 to 60Hz Resistance 200 0 0 1 1 2 5 digits 2 000K 1 1 2 3 digits 20 00k 10 200 0k 100 2 000M 1k 20 00M 10k 2 0 5 digits Maximum In...

Страница 4: ...tion when working with voltages above 25V AC RMS or 60V DC Such voltages pose a shock hazard To avoid false readings that can lead to electrical shock replace batteries when a low battery indicator ap...

Страница 5: ...7 4 1 2000 count LCD display 7 RANGE button 2 Function selector switch 8 MAX Maximum button 3 Clamp 9 Data Hold button 4 COM jack 10 Clamp trigger press to open clamp 5 V jack 11 Arrow markings 6 Bac...

Страница 6: ...The backlight does not automatically power OFF RANGE The meter defaults to auto ranging mode This mode automatically determines the most appropriate measurement range for the testing that is being co...

Страница 7: ...etely Lead guard should be flush with the meter s faceplate TESTING IN CAT III CAT IV MEASUREMENT LOCATIONS Ensure the test lead shield is pressed firmly in place Failure to use the CATIII CATIV shiel...

Страница 8: ...care should be taken to ensure that the clamp is completely closed with trigger 10 fully released and that the wire passes perpendicularly through the center of the clamp in line with the arrow markin...

Страница 9: ...sure voltage The meter will auto range to display the measurement in the most appropriate range NOTE If appears on the LCD the test leads are being applied to the circuit in reverse Swap the position...

Страница 10: ...to display the measurement in the most appropriate range NOTE When in a Resistance setting and the test leads are open not connected across a resistor or when a failed resistor is under test the disp...

Страница 11: ...ple tip and the object being measured When thermocouple tip and object are in thermal equilibrium the measurement on the display will stabilize The meter will auto range to display the measurement in...

Страница 12: ...ns before using MAINTENANCE BATTERY REPLACEMENT When indicator is displayed on LCD batteries must be replaced 1 Remove screw from battery door 2 Replace 3 x AAA batteries note proper polarity 3 Replac...

Страница 13: ...ing the limits mentioned in the General Specifications section allow the meter to return to normal operating conditions before using WARRANTY www kleintools com warranty DISPOSAL RECYCLE Do not place...

Отзывы: