7 Operation of the pyrometer
Figure 5: Connecting cable
Brown
Blue
Black
Figure 6: Pyrometer - Connection
Plug pin(cable)
Plug pin (pyrometer)
Meaning
Brown
Brown
+24 V Supply voltage (DC)
Blue
Blue
0 V Supply voltage (DC)
Black
Black
Switch output
Green/Yellow
Housing
PE
The switch output applies the following voltages:
• Up to the threshold 0 V
• Exceeding the threshold approx. 2 V below the power supply voltage
The internal resistance is 1 k
Ω
. The output is short-circuit proof.
X
The pyrometer is ready for use and can be switched on.
7
Operation of the pyrometer
7.1
Adjust the switching mark
The potentiometer at the rear side of the device helps to adjust the switching marks. The switching state is
shown via LED.
The LED at the rear sight of the device lights by reaching or exceeding the pre-adjusted temperature switch
marks “HIGH” .
With help of a suitable screw driver the switch level of the pyrometer can be adjusted. With reaching the left
catch the switch mark is adjusted to the highest temperature, with the right catch the lowest temperature.
KS 218 - TS KG 218 - TS