background image

36445N3 (02-09) 

OPERATION

MACHINE COMPONENTS

1.  Recovery Tank 
2.  Solution Tank 
3.  Recovery Tank Lid 
4.  Solution Tank Lid 
5.  Vacuum Switches 
6.  Pump Switch 
7.  Heater Switches 
8.  Heater On Indicators 

9.  Power Cord Connectors 
10.  Empty-Out Nozzle 
11.  Pressure adjustment Valve 
12.  Latches 
13.  Recovery Tank Drain 
14.  Separate Circuit Indicator Light 
15.  Solution Hose Connector 
16.  Preheat / Clean Valve 

MACHINE SETUP 

1.  Carefully check carton for signs of damage. 

Report damages at once to carrier. The machine 
is shipped fully assembled and is ready for use. 

2.  Connect hoses and tool to be used (Figure1). 

3.  Using a clean bucket or hose, fill solution tank 

with 41 liters (11 gallons) of hot water, 60° C 
(140° F) maximum (Figure 2). 

  WARNING: Flammable materials can cause an 

explosion or fire. Do not use flammable materials 
in tank(s). 

4.  Add a recommended cleaning chemical. 

FOR SAFETY: When using machine, follow 
mixing and handling instructions on chemical 
containers.

Fig. 1 

 

Fig. 2 

 4 

 3 

14

 

 6 

 9 

 8 

 2 

10

 

13

 

 1 

 5 

 8 

12

 

11

 

15

 

16

 

 5 

 7 

 7 

Содержание 36445N3

Страница 1: ... Rev 00 02 09 36445N3 Carpet and Upholstery Cleaner Model No 36445N3 11 gal Extractor KLEENRITE 1122 MAPLE STREET MADERA CA 93637 U S A FAX 1 559 673 5725 CUSTOMER SERVICE 1 800 241 4865 Operator and Parts Manual ...

Страница 2: ...es may be ordered by phone or mail from any authorized parts and service center distributor or directly from Kleenrite This machine will provide excellent service However the best results will be obtained at minimum costs if The machine is operated with reasonable care The machine is maintained regularly per the maintenance instructions provided The machine is maintained with manufacturer supplied...

Страница 3: ...ands Keep cord away from heated surfaces Report machine damage or faulty operation immediately Follow mixing and handling instructions on chemical containers Connect hoses before turning on pump Be sure chemicals are safe and non toxic 4 Before leaving or servicing machine Turn off machine Unplug cord from wall outlet 5 When servicing machine Unplug cord from wall outlet Avoid moving parts Do not ...

Страница 4: ...SETUP 1 Carefully check carton for signs of damage Report damages at once to carrier The machine is shipped fully assembled and is ready for use 2 Connect hoses and tool to be used Figure1 3 Using a clean bucket or hose fill solution tank with 41 liters 11 gallons of hot water 60 C 140 F maximum Figure 2 WARNING Flammable materials can cause an explosion or fire Do not use flammable materials in t...

Страница 5: ... This will preheat the entire contents of the solution tank CLEANING CARPETS 1 Activate vacuum pump and heater switches and turn preheat valve to clean position Figure 5 2 Take carpet cleaning wand in hand and squeeze valve trigger while moving the tool in short forward and backward strokes Figure 6 WHILE OPERATING 1 Overlap each path by 50 mm 2 in Warning Flammable materials or reactive metals ca...

Страница 6: ...ater at the end of the day DRAINING SOLUTION TANK 1 Remove empty out nozzle from its storage bracket Figure 10 and attach to end of solution hose 2 Place empty out nozzle over a bucket and turn on pump until all the solution has been pumped from solution tank 3 Replace empty out nozzle to its storage location FREEZE PROTECTION 1 After draining solution tank as described in steps one and two in the...

Страница 7: ... 4 Inspect cord and cord grip for damage Replace immediately if damaged 5 Lubricate metal shaft on recovery tank drain with water resistant oil 6 Lubricate female hose couplers with lightweight oil MONTHLY MAINTENANCE Every 80 Hours of Operation 1 Lubricate wheels with water resistant oil 2 Inspect machine for water leaks and loose hardware QUARTERLY MAINTENANCE Every 250 hours of Operation Check ...

Страница 8: ...ect quick couplers Vacuum motor does not operate Loose or broken wiring Contact Service Center Faulty vacuum switch Contact Service Center Defective vacuum motor Contact Service Center Worn carbon brushes Contact Service Center Poor solution pick up Recovery tank drain valve open Close valve Defective recovery tank lid gasket Replace gasket Clogged float shut off screen Remove recovery tank lid an...

Страница 9: ... TANK CAPACITY 38L 10 gal SOLUTION PUMP 120 V 20 68 bar 300psi 2 19 A VACUUM MOTORS 2 3 STAGE PARALLEL 2 120 V 12 1 A 1452 W HEATER 2 x 120v 8 3 A 1000W SEALED WATER LIFT 3454 mm 136 in TOTAL POWER CONSUMPTION CIR 1 120V 20 2A 2424W CIR 2 120V 19A 2280W POWER CORDS 2 7 6m 25 ft 3 12 DECIBEL RATING 3 METERS 10 FT FROM MACHINE ON CARPET 68 db A 711 mm 28 in 1016 mm 40 in 450 mm 17 7 in 902 mm 35 5 i...

Страница 10: ...36445N3 02 09 10 ELECTRICAL DIAGRAM 36445N3 120 V WIRING DIAGRAM ...

Страница 11: ...36445N3 02 09 11 PARTS LIST 36445N3 TANK GROUP ...

Страница 12: ...8 SOC BR ST TH 1 PART DESCRIPTION QTY G 03 19 O RING VITON 2 020 BLKHD 1 J 48GRANITE LID SOLUTION EDGE 2 3 GREY GRANITE 1 J 49GRYGRNT LID MEGA E3 ROTO GREY GRANITE 1 J 57 5 SPACER ROTO 3 OD X 2 4 ID 1 K 09 1 CORD 25 12 3 SJT YELLOW W LOCK 2 K 13 2 LIGHT GREEN ROUND 1 K 13 3 LIGHT RED ROUND 2 K 16 96 BUSHING RELIEF 1 2 NPT 2 K 16 97 NUT NYLON BUSHING REL 1 2 2 K 21W SWITCH SPST WATER RESIS 5 K 28 0...

Страница 13: ...36445N3 02 09 13 PARTS LIST 36445N3 BASE GROUP ...

Страница 14: ...HUT OFF 1 PART DESCRIPTION QTY G 25 15 VALVE BALL 2 WAY 1 4 FPT 1 G 37 VALVE VAC SHUT OFF DUAL 1 J 45BLK PMP MNT DRILD PAR VAC SILNCE BLCK ROTO 1 K 17 4 CLAMP NYLON CABLE 1 4 2 K 17 5 CLAMPS NYLON CABLE 3 8 2 K 25 82 THERMOSTAT 190 SPST 2 K 25 83 THERMOSTAT 230 SPST 2 M 0563 8 BRACKET MTR STARTER CAP 1 M 0790 5 AXIL ROD 1 2 ECONO 1 M 0791 AXIL ROD 1 2 1 M 0791 01 BRACKET PRES RELFVAL 1 M 0791 3 PI...

Страница 15: ...MP 300PSI 1 4HP AC CMP 220V110CAM 60HZ XXX 1 2 SL 28 300A MOTOR 300PSI AC CMP 110V 110CAM 60HZ XXX 1 2 SL 28 410MTR MOTOR 300PSI AC CMP 100V 116CAM 50 60HZ XXX 1 2 SL 28 425MTR MOTOR 300PSI AC CMP 220V 110CAM 60HZ XXX 1 2 SL 28 450MTRCE MOTOR 300PSI AC CMP 220V 125CAM 50HZ XXX 3 SL 28 KIT A PUMPTEC KIT PLUNGER SEAL XXX XXX XXX XXX 4 SL 28 KIT B PUMP KIT VALVE O RING XXX XXX XXX XXX 2 SL 28 KIT C P...

Страница 16: ...LBOW 1 4 NPT 1 D 41 NIPPLE 1 4 NPT CLOSE BR 1 F 09 Q C 1 4 PLUG BR SHUT OFF 1 G 23 VALVE KNGSTN STD S BEND 1 PART DESCRIPTION QTY G 23 5 VALVE KNSTN HP S BEND 1 H 02 5 BODY TEE JET 1 4 BRASS 2 H 03 CAP NUT TEE JET BRASS 2 H 18 5 JET 11003 TEE BRASS 2 H 18 7 JET 110015 E TEE BRASS 2 M 16 5 HOE HANDLE ECONO FLRTL 1 M 16 5A U CLAMP SUPP HOE HNDL EC 1 M 20 WAND S BND FLTL COM W HD 1 SC 82 TRIGGER COMP...

Страница 17: ...G 04 5 GUIDE VALVE STEM HEX BRASS 1 G 05 5 STEM VALVE SS 4 DETAIL TOOL 1 G 08 5 SPRING VALVE 4 UPH TOOL 1 PART Description QTY GR 2 006N70 O RING 2 006 BUNA 70DR 2 GR 2 011N70 O RING 2 011 BUNA 70DR 1 GR 2 013N70 O RING 2 013 BUNA 70DR 1 H 03 5 CAP NUT TEE JET POLYPRO 1 H 18 8 JET 110015 STD FLAT SPRYTIP PLSTIC 1 J 62 VALVE 4 DETAIL TOOL AS MOLDED 1 J 63 TRIGGER 4 DETAIL TOOL 1 J 64 ELBOW 4 DETAIL...

Страница 18: ... has been established prior to the request the part will be shipped on an Open Account basis part plus freight A Return Authorization must be requested at the time of order so that the suspected defective part can be returned freight prepaid to Kleenrite for warranty consideration If after receiving the part Kleenrite determines that the part has a manufacturing defect and can be repaired the part...

Страница 19: ...36445N3 02 09 19 ...

Страница 20: ...art s other than genuine Kleenrite parts will immediately void this and all warranties Filters brass fittings seals o rings and quick disconnects are considered expendable in normal use and are not covered by this warranty Dry cleaning solvents cannot be used in the Edge This warranty shall not cover any Edge machine housing part or assembly if there is evidence of misuse alteration owner neglect ...

Страница 21: ...36445N3 02 09 21 Purchased From Distributor ...

Страница 22: ...art s other than genuine Kleenrite parts will immediately void this and all warranties Filters brass fittings seals o rings and quick disconnects are considered expendable in normal use and are not covered by this warranty Dry cleaning solvents cannot be used in the Edge This warranty shall not cover any Edge machine housing part or assembly if there is evidence of misuse alteration owner neglect ...

Страница 23: ...36445N3 02 09 23 Purchased From Distributor ...

Отзывы: