SL6KLN1AU_ara_en_a_638_X.doc – 15.02.08
Seite 10 von 49
4 COMPONENTS
4.1 Operating
module
The buttons and the display are located on the operating module.
4.2 Display
module
(optional)
The programme sequence, the rinse symbols, refill indicators and
remaining running time are displayed via the optional display module.
4.3 Power
module
4.3.1
Tap turned off
If the filling level (f1) is not reached after 3½ minutes, the control re-
mains in this position and waits until the level has been reached. The
buzzer sounds to indicate a filling fault. The message “Check water
supply” is displayed on appliances with a front display.
If the tap is turned on after the 3½ minutes, the appliance is filled only
with untreated water in this filling step.
4.3.2 Regeneration
electronics
The electronics determine, in comparison with the water hardness set
on the appliance, the volume of water which is possible until the
softening system is exhausted.
The number of rinse cycles is counted. Regeneration then takes place
once the maximum possible number of rinse cycles has been
reached.
The sequence characteristics of the regeneration electronics are des-
cribed under Initial start-up / Replacing the electronics.
4.3.3 Warm
water
detection
If the water running into the final rinse cycle is hotter than 45 °C, the
temperature in the final rinse cycle is increased to 72 °C in order to
increase the inherent heat of the dishes. The heat exchanger is not
filled.
1 - 6 to the power module / refill indicator
7 - 9 to the display module
1 - 3 to the operating module