P/N 1.07080 Revision G 3 of 8
Table 2. Physical and Electrical Specifications
Grounding Instructions:
This product should be grounded. In the event of an electrical short circuit, grounding reduces the risk of electric shock
by providing an escape wire for the electric current. This product is equipped with a cord having a grounding wire with a
grounding plug. The plug must be plugged into an outlet that is properly installed and grounded.
DANGER
—Improper use of the grounding plug can result in a risk of electric shock.
Check with a qualified electrician or serviceman if the grounding instructions are not completely understood, or if in doubt as
to whether the product is properly grounded.
This product is factory equipped with a specific power supply to permit connection
to a proper electric circuit. Make sure that the product is connected to an outlet
having the same configuration as the plug. No adaptor should be used with this
product. Do not modify the plug provided—if it will not fit the outlet, have the
proper outlet installed by a qualified electrician.
Safety Precautions:
• Use only manufacturer approved parts and maintenance procedures to service the unit. Refer to the FLEX-MATE
®
K500
Service Manual.
• Read and adhere to all warnings and instructions listed on the FLEX-MATE
®
K500 and this Users Manual.
• If you suspect the FLEX-MATE
®
K500
is not working properly, unplug the unit and refer to the Service Manual.
• If you detect a flaw of any type in the power cord, immediately unplug the transformer from wall.
• Use only the external power supply provided with the FLEX-MATE
®
K500
in order to meet the requirement of UL 60601-1.
Package Contents:
1 FLEX-MATE
®
K500
1 Users Manual
1 Service Manual
1 Package of soft goods
1 Tape measure
Product Description:
The purpose of the FLEX-MATE
®
K500
is to provide continuous passive motion to the knee or hip joint to increase
circulation, range of motion, and to prevent scarring in the joint. The FLEX-MATE
®
K500 is an anatomically aligned CPM
which mirrors the path of the knee as it goes through its range of motion from full–or hyper-extension through full flexion.
Table 1. Symbols used on the
FLEX-MATE
®
K500
UL/C-UL Classification with respect to electric shock, fire, and mechanical hazards only in accordance with UL
60601-1/CAN/CSA C22.2 No. 601.1. Meets UL 1431 Standards for Personal Hygiene and Healthcare Appliances.
Symbol
Direct Current
Attention: Consult User’s manual before use.
Class I, Type B, Continuous Operation.
Not suitable with flammable anesthetics.
Description
Size Setup for Use:
Length
Width
Height
Weight:
Without accessories
With accessories
Fully packaged
Electrical Specifications:
Input
Environmental Requirements:
Temperature:
Operating
Transport & Storage
Humidity:
Operating
Transport & Storage
Atmospheric Pressure:
Standards Compliance
39”
13”
22”
26 lbs.
27 lbs.
34 lbs.
120 VAC 60Hz 25 W
50
o
F to 95
o
F (10
o
C to 35
o
C)
-40
o
F to 158
o
F (-40
o
C to 70
o
C)
30 – 75% R.H.
10 – 100% R.H., non-condensing
700 hPa to 1060 hPa
Designed to conform to applicable
requirements of:
UL 60601-1, UL 1431
CSA C22.2 / No. 601.1
Grounded
Outlet
Grounded
Outlet Box
4038 Weaver Court East
Hilliard, OH 43026
Ph: (614) 921-8866
Fx: (614) 921-8877
Toll Free: (866) 532-3534