3.2  Scope of delivery 

970716Additional package KLAROconnect indoor antenna I-cabinet PP, A-cabinet PP 

970717Additional package KLAROconnect indoor antennaI-cabinet1/2/3, A-cabinet4/5, M-technology 

970718Additional package KLAROconnect indoor antenna A-Uni. / -pillar

 

970719Additional package KLAROconnect external aerialA-cabinet3/4/5/uni / column 

 

Article  Quantity  Designation 

970716  970717  970718  970719 

901471  1 STK  KLAROconnect 

 

 

 

 

982223  1 STK  Data cable 

 

 

 

 

901474  1 STK  LTE indoor antenna 

 

 

 

 

901476  1 STK  LTE outdoor antenna 

 

 

 

 

980194  10 CM  Velcro tape 

 

 

 

 

901475  1 STK  Ethernet extension cable 

 

 

 

 

980314  1 STK  Cable gland M16 

 

 

 

 

980311  1 STK  Locknut M16 

 

 

 

 

 

● Included in the 

scope of delivery 

○ not 

included in the scope of delivery 

 

The following is a pictorial representation of components  from the KLARO WebMonitor® packages 

(Velcro tape, cable gland and locknut are not shown). 

 

 

 

 

Illustration 1

901474 LTE indoor antenna with tilt joint (always 

included as standard) 

 

Picture 2

901476 LTE outdoor antenna SMA 4G  

 

 

 

 

 

Illustration 3

901475 Ethernet extension cable FTP Cat6 right-

angled 0.5m (as standard for I-cabinet PP)

 

Illustration 4

982223 Data cable KLAROconnect 

KLAROcontrol.S/M

 

 

 

 

Operating Instructions KLAROconnect 

 
 

Status 06/2022 

KLARO GmbH  

  Page 7/21 

3.3  Mounting KLAROconnect 

3.3.1  Velcro fastening 

 

 

The Velcro tape included with the KLAROconnect is used 

to mount the communication module. 

Note: The glued areas must be made dust-free before 

applying the Velcro tape. 

 

 

3.3.2  Mounting adapter (available from WAGO) 

The KLAROconnect can be mounted on a DIN 35 rail using two mounting feet (WAGO 209-123). To 

do this, the mounting feet are mounted with the screws on the underside in the holes provided. 

 

 

 

 

Содержание 970716

Страница 1: ...GERMAN DESIGN AND ENGINEERING KLAROconnect Operating manual 317 EN 0622 Direct access to the plant data Operational safety for the wastewater treatment plant 4G LAN We provide clear water...

Страница 2: ...Operating Instructions KLAROconnect Status 06 2022 KLARO GmbH Page 2 21 Original operating instructions Communication module KLAROcon nect...

Страница 3: ...ESCRIPTION 10 5 5 1 ELECTRICAL INTERFACES 10 5 1 1 Power supply and serial interface X6 10 5 1 2 USB 2 0 11 5 1 3 LAN Ethernet connection 11 5 1 4 SMA antenna connection 11 5 2 OPERATING ELEMENTS 12 5...

Страница 4: ...s or typographical errors in the documentation is excluded Should you find any incompleteness and or errors please inform us at the above address In preparing these instructions care was taken to ensu...

Страница 5: ...https klaro webmonitor de Via KLARO connect all operation relevant data such as settings events and operating hour meter readings of the KLAROcontrol S and KLAROcontrol M are transmitted to the KLARO...

Страница 6: ...STK Data cable 901474 1 STK LTE indoor antenna 901476 1 STK LTE outdoor antenna 980194 10 CM Velcro tape 901475 1 STK Ethernet extension cable 980314 1 STK Cable gland M16 980311 1 STK Locknut M16 Inc...

Страница 7: ...KLAROconnect is used to mount the communication module Note The glued areas must be made dust free before applying the Velcro tape 3 3 2 Mounting adapter available from WAGO The KLAROconnect can be mo...

Страница 8: ...ons KLAROconnect Status 06 2022 KLARO GmbH Page 8 21 Basic connection diagram 1 Control unit KLAROcontrol M or KLAROcontrol S 2 KLAROconnect communication module 3 Antenna 4 Data cable serial cable po...

Страница 9: ...n KLAROconnect After the card has been inserted KLAROconnect can be connected to the power supply switch on KLAROcontrol The connection with KLAROcontrol is fully automatic A WEB symbol appears in the...

Страница 10: ...cro SD card slot LED6 Display LED1 Display without function LED5 Display LED2 Display without function Figure 5 Interface overview 5 1 Electrical interfaces 5 1 1 Power supply and serial interface X6...

Страница 11: ...atus of the transmission If this LED1 flashes or flickers then data is being transmitted LED2 left lights up when there is a connection to a network LED1 is the right hand LED LED2 the left hand LED i...

Страница 12: ...d for mini SIM Figure 10Insert the mini SIM card into the KLAROconnect Removing and inserting the SIM card during operation requires initialisation of the KLAROconnect software Therefore the KLAROconn...

Страница 13: ...are the switching states ON and OFF In the ON state LED6 lights up green Interval 100ms on 100ms on 800ms off normal function In the event of a reset or similar the LED lights up continuously for a fe...

Страница 14: ...enu can also be called up alternatively via the assigned IP in the DHCP server of the router 6 2 SIM profile configuration A SIM card profile with details of the APN of the provider can be created via...

Страница 15: ...y on the screen press the F5 key Then create a new profile with the Add button 4 A new window Mobile broadband opens The connection name can be freely assigned The fields Connection name and APN must...

Страница 16: ...th a red background the attempt was not suc cessful and the procedure must be repeated as described in the instructions Then close the win dow with the Close or X button 7 If no further configuration...

Страница 17: ...on is established Responses from the KLAROcontrol are passed on to the WebMonitor via the KLAROconnect using the websocket ws 6 3 1 Websocket URI Configuration Guide 1 Call up the KLAROconnect menu vi...

Страница 18: ...o the power supply 5 Firmware is automatically installed from the micro SD card The process takes approx 7 to 10 minutes 6 After the process is completed KLAROconnect switches off automatically Green...

Страница 19: ...B41 WCDMA B1 B2 B4 B5 B6 B8 B19 GSM B2 B3 B5 B8 Voice Speech Codec Modes HR FR EFR AMR AMR WB Echo Arithmeti c Echo Cancellati on Noise Suppression Audio Digital Audio and VoLTE Voice over LTE Opti o...

Страница 20: ...dBm 10 MHz LTE B8 99 8 dBm 10 MHz LTE B12 99 8 dBm 10 MHz LTE B13 99 5 dBm 10 MHz LTE B18 100 dBm 10 MHz LTE B19 99 9 dBm 10 MHz LTE B20 99 8 dBm 10 MHz LTE B25 100 dBm 10 MHz LTE B26 99 5 dBm 10 MHz...

Страница 21: ...joint approx 137 00 mm without tilt joint Diameter approx 19 60 mm tip approx 21 60 mm max approx 13 50 mm SMA 8 4 LTE outdoor antenna Specification LTE Band 1 10 12 20 23 25 30 33 41 44 Frequency ra...

Страница 22: ...plate Type plate contains information on product designation type item number art no serial number in writing and bar code SN power supply U software version SW hardware version HW The MAC address is...

Страница 23: ......

Страница 24: ...ill Kedrinski rangizzz KLARO GmbH Bayreuth 2022 KLARO GmbH klaro_gmbh KLARO GmbH E Mail Adresse info klaro eu Message Further information under www klaro eu Internet Technical hotline 49 0 921 16279 3...

Отзывы: