3. Mixer Setup
• •
MADI Mode
selects either AES10-1991/56-channel or
AES10-2003/64-channel operation
• •
MADI Chan In
selects the start channel for the block of
32-ch that will be available for input routing: MADI ch 01,
ch 09, ch 17, ch 25, ch 33 (in 64 channel mode)
• •
MADI Chan Out
selects the start channel for the block
of 32-ch that will be replaced in the MADI output stream:
MADI ch 01, ch 09, ch 17, ch 25, ch 33 (in 64 channel mode)
• •
MADI Source
selection boxes for MADI connection – fiber-
optic and/or coaxial. Select both for redundant use of coaxial
and fiber-optic connections.
• •
DN32-MADI card can be selected as the clock source on
the mixer’s Setup/config page. In that case, the M32 will
be slaved to the MADI clock received on BNC input or
fiber-optic inputs. Note that this may require rebooting the
console if the internal and external clock rates are different
(i.e. 44.1/48 kHz).
4. Connector Plate
• •
Dual BNC coaxial input and outputs, 75 Ohm
• •
Cables up to 100 m in length may be used.
• •
SC-plug duplex fiber-optic connector (IEC874-19)
• •
Use SC duplex connectors and multimode fiber-
optic cable with 50-micron core / 125-micron
cladding diameters, or a 62.5-micron core /
125-micron cladding diameters.
• •
Cables up to 500 m in length recommended.
• •
2x small handles for removing the expansion card
from the slot
• •
2x M3x6 screws for fastening the card in the slot
• •
3 countersunk M3 screws for fixing the pcb.
Don’t loosen these!
14
15
Quick Start Guide
EXPANSION CARD DN32-MADI
Содержание DN32-MADI
Страница 28: ......